To LUGNET HomepageTo LUGNET News HomepageTo LUGNET Guide Homepage
 Help on Searching
 
Post new message to lugnet.robotics.rcxOpen lugnet.robotics.rcx in your NNTP NewsreaderTo LUGNET News Traffic PageSign In (Members)
 Robotics / RCX / Search Results: range USB IR long Tower
 Results 861 – 880 of about 2200.
Search took 0.02 CPU seconds. 

Messages:  Full | Brief | Compact
Sort:  Prefer Newer | Prefer Older | Best Match

  Re: Problem to send long messages from RCX to PC via com Hack
 
I don't know if this is would be of any help, as it uses a different approach, but I thought I'd pass it along anyway.... Bi-directional Bluetooth to IR translator - (URL) (PDF format: (URL) ) While this solution doesn't allow both the serial and IR (...) (16 years ago, 28-Jun-08, to lugnet.robotics.rcx.legos)
 

ir, long
(score: 3.294)

  Problem to send long messages from RCX to PC via com Hack
 
Hi, Once again i am back about RCX and BT-Connection. Receiving messages from the PC via BT to the RCX is OK. But if I send messages from the RCX to the PC with 4800 Baud i get only 4 Bytes. So I go back to 2400 Baud, forget BT and make a serial (...) (16 years ago, 10-Jun-08, to lugnet.robotics.rcx.legos)
 

ir, long
(score: 3.293)

  Re: Problem to send long messages from RCX to PC via com Hack
 
(...) Dear Matthew I have found the problem. It was in kernel\lnp-locical.c -> cheking the echo was the problem solution: echo OFF it is a rough solution, but it works changes 1) rx_handler(void) ... // echos of own bytes -> collision detection // (...) (16 years ago, 29-Jun-08, to lugnet.robotics.rcx.legos)
 

ir, long
(score: 3.293)

  Re: Some goals, ideas, etc. for a new bytecode interpreter (long)
 
(...) Sure, but that's what zero padding is for. Since the opcode is IR-only, you don't care too much about length. The only length restriction comes from the second digit of the opcode, assuming you're using the ROM to receive incoming IR data. (...) (25 years ago, 10-May-99, to lugnet.robotics.rcx)
 

ir, long
(score: 3.293)

  Re: Displaying info while debugging
 
Thanks a lot Ralph, And I'm sure you're right. I tried this: 10000 VALUE CTR : test 100 0 DO I CR . CTR 0 DO LOOP LOOP ; For CTR > 11000, the numbers are displayed one at a time. Below 11000, they're displayed in batch. So, it probably means that (...) (22 years ago, 3-Jul-02, to lugnet.robotics.rcx.pbforth)
 

ir, long
(score: 3.293)

  Re: Sending Commands to Spybot from RCX - Question from a Beginner to Comm area.
 
(...) First of all, my apologies for not answering you via email. I've been a bit busy at work. I needed to run some tests myself before I could properly respond as well. The 0x9223 from the RCX happens to match the IR sent out by the Spybot (...) (20 years ago, 28-Jan-05, to lugnet.robotics.spybotics, lugnet.robotics, lugnet.robotics.rcx, lugnet.robotics.rcx.nqc)
 

ir, long
(score: 3.293)

  sensor questions plus
 
You said to keep asking questions. I'm taking you at your word. Questions I've got. o - Sensor questions: Could you explain how the sensor code works? How does it interact with the ROM. Is this (ROM stuff) documented elsewhere? What does SENSOR_READ (...) (24 years ago, 3-May-00, to lugnet.robotics.rcx.pbforth)
 

ir, long
(score: 3.292)

  Function list and Command List for LegOS 0.2.3 (Long Post...)
 
Hi All, I am eagerly awaiting the full documentation for 0.2.3, in the mean time, I culled together some info from the readme files for 0.2.3, looking through some of the source files and the old 0.1.7 documentation that is on line. I find it (...) (24 years ago, 16-Apr-00, to lugnet.robotics.rcx.legos)  
 

ir, long
(score: 3.292)

  RE: Drive R/C Servos with the RCX and pbForth (long)
 
(...) I hear you, John. Learning a new language can be a bit tricky, and I won't go into the details of why I think it's a good idea to learn different languages to get the benefit of different ways of thinking about problems...oops, don't get me (...) (25 years ago, 12-Feb-00, to lugnet.robotics, lugnet.robotics.rcx.pbforth, lugnet.robotics.rcx)
 

ir, long
(score: 3.292)

  Re: Powering trains w/ RCX
 
Uhhhh, gee, I just used some extra-long wires I got from Dacta to extend the console over to next to the couch, and plugged it in there ;-) But yeah, I want to get a couple of IR remotes too, for when I take an 8448 to work, and for my future train (...) (25 years ago, 21-Dec-99, to lugnet.trains, lugnet.robotics.rcx)
 

ir, long
(score: 3.292)

  Re: legOS make newbe question
 
(...) I'm sorry it took so long to reply, Phil, but as a non-windows user, well, I didn't see much in the initial messages that led me to think I could help. From what I've seen, this is the cause of the error- the two Makefiles (Makefile and (...) (25 years ago, 22-Jun-99, to lugnet.robotics.rcx.legos)
 

ir, long
(score: 3.292)

  Some goals, ideas, etc. for a new bytecode interpreter (long)
 
Forgive me while I think out load here. I'd like some feedback on some goals and ideas I've thought of for a new bytecode interpreter. Any critiques, comments, opinions, recommendations, or additions are welcome: I would hope that the new system (...) (25 years ago, 8-May-99, to lugnet.robotics.rcx)
 

ir, long
(score: 3.291)

  Re: NQC vs Spirit communication speed
 
The retry timing for RCX_Link uses a dynamic backoff, which is a good general purpose solution if you're going to be sending lots of packets (like a typical NQC download) and the latency through the serial driver is unknown and/or unpredictable (...) (23 years ago, 11-May-01, to lugnet.robotics.rcx.nqc)
 

ir, long
(score: 3.291)

  leJOS & LDCC IRP
 
Brian B. Alano wrote: I'm writing a leJOS package to support the LDCC IR Protocol. I've been testing it against Full Throttle. It works fine with the speed controls, but doesn't even seem to see packets for the function commands, stop, or power (...) (21 years ago, 12-Sep-03, to lugnet.robotics.rcx.java, lugnet.trains)
 

ir, long
(score: 3.291)

  Threaded LNP problems
 
Hi, I've written a small program with a few rcx's moving around trying to communicate with each other through IR. Every Robot is supposed to send it's lnp address every 100ms in a seperate thread, listen for other robots in another thread and move (...) (21 years ago, 19-Mar-04, to lugnet.robotics.rcx.legos)
 

ir, long
(score: 3.291)

  Thoughts & Issues w/ Vision Command
 
Hello Does the Vision Command camera send messages to the RCX via the IR port ? I would assume this would be the case but I just wanted to make sure. Also, does Vision Command come pre-configured with a default program or do you have to configure it (...) (24 years ago, 8-Sep-00, to lugnet.robotics.rcx.nqc)
 

ir, long
(score: 3.291)

  Re: decoding a message sent by an RCX
 
(...) Yes, you are correct - 11 bits total per byte. And yes, this is very non-standard. I believe the signal is inverted - meaning that IR light is present for "0" bits, and no light for "1" bits. But I'm going from memory here and haven't looked (...) (25 years ago, 4-Sep-99, to lugnet.robotics.rcx.nqc)
 

ir, long
(score: 3.291)

  Turning power off?
 
To my dismay, I discovered this morning that the batteries of the RCX were empty. And it's sunday :-( It is possible that I forgot to turn it off, yesterday evening. But aside from this, I use the sequence LCD_CLEAR LCD_REFRESH POWER_OFF to turn the (...) (25 years ago, 12-Mar-00, to lugnet.robotics.rcx.pbforth)
 

ir, long
(score: 3.291)

  solaris + legOS
 
Hello, I'm trying to get legOS to work on solaris. I'm having troubles. I've got the cross compiler installed. I'm having the same problem everyone else who's tried it on Solaris: legOS/util/dll-src/loader.c gives problems me an error with the (...) (24 years ago, 27-Jul-00, to lugnet.robotics.rcx.legos)
 

ir, long
(score: 3.290)

  solaris + legOS
 
Hello, I'm trying to get legOS to work on solaris. I'm having troubles. I've got the cross compiler installed. I'm having the same problem everyone else who's tried it on Solaris: legOS/util/dll-src/loader.c gives problems me an error with the (...) (24 years ago, 27-Jul-00, to lugnet.robotics.rcx.legos)
 

ir, long
(score: 3.290)

More:  Next Page >>