To LUGNET HomepageTo LUGNET News HomepageTo LUGNET Guide Homepage
 Help on Searching
 
Post new message to lugnet.robotics.rcxOpen lugnet.robotics.rcx in your NNTP NewsreaderTo LUGNET News Traffic PageSign In (Members)
 Robotics / RCX / Search Results: range USB IR long Tower
 Results 1621 – 1640 of 2193.
Search took 0.01 CPU seconds. 

Messages:  Full | Brief | Compact
Sort:  Prefer Newer | Prefer Older | Best Match

  Re: text location for apps and q?
 
Hello, (...) No they don't have a separate address space. I think the limit is 19456 bytes for the kernel, and this is caused by a limitation of the ROM, which is used to download the firmware (kernel). It loads it to the address range 8000-cc00. (...) (24 years ago, 30-Oct-00, to lugnet.robotics.rcx.legos)
 

range
(score: 0.350)

  Connecting 2 RCXs
 
The IR interface is one way to establish a "connection" via messages between 2 RCXs and it works fine if both of the RCXs will receive a message - directly or by multiple reflections within the room. However, it is a slow communication. My problem (...) (24 years ago, 19-Oct-00, to lugnet.robotics.rcx.nqc)
 

ir
(score: 0.350)

  Re: LNP Packet Handlers on RCX
 
(...) started dabbling (...) interrupts (...) from the (...) Yes. lnp_integrity_handler() and lnp_address_handler()s are still called from IR byte receiving interrupt. No problem in the actual implementation (taking care of it) but it should be a (...) (24 years ago, 20-Oct-00, to lugnet.robotics.rcx.legos)
 

ir
(score: 0.350)

  Re: Help with Clock
 
Hi Scott, (...) yes. It is like a big wall clock that shows milliseconds. (...) System.currentTimeMillis(); Note that this is a long integer. If you need more than one timer you can remember the time in variables and then compute the difference, (...) (22 years ago, 1-Sep-02, to lugnet.robotics.rcx.java)
 

long
(score: 0.350)

  Re: Painful details on RCX.pm problems
 
Luis, I found a half dead 9V battery and put it in my tower. I am getting similar results, except I hang after the first or second reading. Something like: 0) 41 1) 41 And that is it. I for got to ask is it connisistantly after the 4th one things go (...) (24 years ago, 8-Nov-00, to lugnet.robotics.rcx)
 

tower
(score: 0.350)

  Re: Continous operation
 
(...) SNIP (...) Thanks for the help. Sounds like the RCX works great for long periods of time. Andreas (22 years ago, 9-Sep-02, to lugnet.robotics.rcx)
 

long
(score: 0.350)

  Re: RCX.pm questions [and Linux RCX GUI question]
 
So, I have some more questions to anyone who wants to answer them :) (John, hope you are listening ;) 1) Do I need to recreate $rcx after a while? It looks to me that under many circumstances, repeated calls to the RCX will fail to cause the tower (...) (24 years ago, 6-Nov-00, to lugnet.robotics.rcx)
 

tower
(score: 0.349)

  Re: LinuxPPC and "No response from RCX" problem
 
(...) Perhaps timing is a problem. Try: nqc -t 1000 -raw 10 This forces a longer (1 second) timeout per packet instead of the dynamic retry timing. Is the output any different? Echo is coming back from the tower, which means communication between (...) (24 years ago, 4-Nov-00, to lugnet.robotics.rcx.nqc)
 

tower
(score: 0.349)

  Re: Warning cleanup questions with gcc3.2
 
(...) I am running 3.1 and got the same error. But for user programs only because a line in boot/config.h is too long. In fact this is no error but just a warning. Looks bad but the code is ok. (...) If you look at the beginning of the file (I think (...) (22 years ago, 5-Sep-02, to lugnet.robotics.rcx.legos)
 

long
(score: 0.349)

  link error with binutils 2.13
 
hi, after a long time having a running legos 0.2.5, with gcc 2.95.2 and binutils 2.9.1, i decided to get legos 0.2.6 and use the opportunity to upgrade gcc to 3.2 and binutils to 2.13. Everything went smoothly (even the firmware seems to load (...) (22 years ago, 2-Sep-02, to lugnet.robotics.rcx.legos)
 

long
(score: 0.349)

  Re: LinuxPPC and "No response from RCX" problem
 
(...) Umm.. note the prompt ;)) I'd done an su root before testing to avoid permissions problems. This seems like a problem with nqc on LinuxPPC 3Q99, but I can't understand quite what it is as the tower obviously works - the green light is visible (...) (24 years ago, 3-Nov-00, to lugnet.robotics.rcx.nqc)
 

tower
(score: 0.349)

  Re: LinuxPPC and "No response from RCX" problem
 
(...) Have you tried using setserial to set the correct baud rate and other options? Also note that when using "su" it sometimes doesn't take over all the settings from the user account that you used to log on. Perhaps the sudo command would work (...) (24 years ago, 4-Nov-00, to lugnet.robotics.rcx.nqc)
 

tower
(score: 0.349)

  Re: Still JAVA and LNP....
 
(...) There is no way to passively listen to the world. This is good for batteries but bad in all other ways. So, your listening code should send a keep-alive on a regular basis to keep the tower from dying. No way around it :| Luis ---...--- "It's (...) (24 years ago, 3-Nov-00, to lugnet.robotics.rcx.legos)
 

tower
(score: 0.349)

  Re: The datalog
 
(...) Dave, I have a question about the datalog. In the manual you state that the createdatalog function creates a datalog of x many points. How much is a point? Is that how many unique entries can be made or an overall 'byte' amount? Is a value (...) (24 years ago, 3-Oct-00, to lugnet.robotics.rcx.nqc)
 

ir
(score: 0.347)

  Re: Sharp GP2D05 Infrared Ranger and the RCX
 
Ooh, you're right. This seems to be too much for battery powered models. Has anybody a better idea? I want to have a sensor with gives a linear (?) signal corresponding to a distance. For an 1-bit boolean signal I saw a plan in elektor 9/2000 (...) (24 years ago, 3-Oct-00, to lugnet.robotics.rcx)
 

ir
(score: 0.347)

  Re: Have a curator for robotics/rcx/legos ? and...
 
Stephen, (...) I'd gladly second that (self-)nomination! (...) I would consider keeping the old group and creating a new one for brickOS. My main reasoning is that there are sure to be queries about previous releases of legOS for quite some time, (...) (22 years ago, 18-Aug-02, to lugnet.admin.curators, lugnet.robotics.rcx.legos)
 

long
(score: 0.346)

  RE: FW: updating Robolab 2.5 - Some testing
 
Hello Colin, In order to get this CD-ROM for 2.5.1 I called Deanna Newell at Pitsco. She was on vacation and they transferred me to some very friendly tech support people. To make a long story short, I pointed out all the patches that need to be (...) (22 years ago, 18-Aug-02, to lugnet.robotics.rcx.robolab, lugnet.dacta)
 

long
(score: 0.346)

  Re: Scout poweroff time out?- Update
 
(...) After a *FEW* hours playing with this thing I've found out the following... It's built in shutdown is set for 15 minutes. Sending an IR code seems to reset this counter. So far I cannot find any way to keep it alive on it's own. If anyone (...) (24 years ago, 30-Sep-00, to lugnet.robotics.rcx.nqc, lugnet.robotics.scout)
 

ir
(score: 0.346)

  RE: updating Robolab 2.5
 
Hello Miles, After all the help you have been to me in the past I am happy to help you. About two months ago I received a CD-ROM from Pitsco with the label 2.5.1 on it. The instructions were very simple "Overlay everything in the current Robolab (...) (22 years ago, 17-Aug-02, to lugnet.robotics.rcx.robolab, lugnet.dacta)
 

long
(score: 0.346)

  TinyVM coding question
 
Folks, I have a question about TinyVM 0.1.3. I am working with the included code (TestReceiver1.java) but have come across some interesting behavior which I hope someone can explain (and offer a solution for). I am tryying to write a simple program (...) (24 years ago, 22-Sep-00, to lugnet.robotics, lugnet.robotics.rcx.java)
 

ir
(score: 0.345)

More:  Next Page >>


©2005 LUGNET. All rights reserved. - hosted by steinbruch.info GbR