 | | Re: BricxCC release 3.3.3.7
|
|
(...) Whoops. I totally screwed that up. I apparently put an old EXE in the ZIP file. I need to seriously improve my configuration management! :-) Sorry about the mixup. I'm not going to release again until I'm sure I've tracked down and fixed the (...) (23 years ago, 15-Feb-02, to lugnet.robotics.rcx.nqc)
|
|
 | | Re: How communication is handled
|
|
(...) (2 URLs) easier to remember :-) BTW, the RCX has a H8/3292 Keep a copy Jürgen (23 years ago, 15-Feb-02, to lugnet.robotics)
|
|
 | | Re: power source
|
|
(...) Actually, it is regulated (speaking as one who has had to replace the fuse that comes before the regulator). Think about it. It has to be. The batteries provide 9V, the MCU requires 5V. If it wasn't regulated, you'd kill it. There is also a (...) (23 years ago, 14-Feb-02, to lugnet.robotics)
|
|
 | | Re: Re: Lost my IR tower
|
|
Stef Mientki has also posted the information here: (URL) along with a wealth of other info! ___...___ Get your own "800" number (...) (23 years ago, 15-Feb-02, to lugnet.robotics)
|
|
 | | Re: Lost my IR Tower
|
|
Stef (...) The IR LEDs are pulsed on and off at 30kHz - that's on top of the 2400bps serial signal. I had to remove that 30kHz signal. That's what the 100nF (on the base of the transistor) is for. The time-constant of the 100nF and the 470R has to (...) (23 years ago, 14-Feb-02, to lugnet.robotics)
|
|
 | | Re: Lost my IR tower
|
|
Hi Thorn Family I would like to see the diagram. I'm told it's at (URL) can email it directly if it's not there. Peter (23 years ago, 14-Feb-02, to lugnet.robotics)
|
|
 | | Re: How communication is handled
|
|
hi Rob, (...) here is some information about IR-tower/communication, also check Kekoa's site mentioned below (URL) (...) check the site of Kekoa (URL) (...) Stef Mientki (23 years ago, 14-Feb-02, to lugnet.robotics)
|
|
 | | RE: How communication is handled
|
|
the better way to know how the IR work is the legOS kernel source. I read it and see that legOS use IRQ for transmiting and receiving message. When legOS receive a message he see first if the activity of the IR transmitter is not true. Then he call (...) (23 years ago, 14-Feb-02, to lugnet.robotics)
|
|
 | | How communication is handled
|
|
Hello everyone! Does anyonk know what the RCX does with IR data it sees from the IR module when it is busy transmitting? I've set the RCX in a situation where I know the IR it was sending could be seen by it's own IR detector, yet it didn't appear (...) (23 years ago, 14-Feb-02, to lugnet.robotics)
|
|
 | | Re: Lost my IR Tower
|
|
(...) It's probably easier to solder the wires on without the diodes. They could probably be put back on easily though. (23 years ago, 14-Feb-02, to lugnet.robotics)
|
|
 | | Single set Technic Power Pulling.
|
|
FUT: lugnet.technic Hi! Here's yet another Tehnic genre booster! Challenge: Build a model that can pull as much load as possible using pieces from _only_one_ official LEGO set! One class for each set so you can all be winners, no matter what set you (...) (23 years ago, 14-Feb-02, to lugnet.technic, lugnet.announce, lugnet.build, lugnet.general, lugnet.robotics)
|
|
 | | Challenge: Technic Model of the Month!
|
|
FUT: lugnet.technic Hi all! I've decided the Technic genre needs a boost so I have made a Technic model of the month competition/challenge similar to ldraw.org's MOTM & SOTM. Each month a winner will be elected by an e-mail voting process. For more (...) (23 years ago, 14-Feb-02, to lugnet.technic, lugnet.announce, lugnet.build, lugnet.general, lugnet.robotics)
|
|
 | | Re: Power to RCX
|
|
(...) Yes, but any regulator would convert power uselessly into heat, probably too much if you use a much higher voltage and draw some current. It would be better to use higher voltage motor controllers directly (if they exist). And of course this (...) (23 years ago, 14-Feb-02, to lugnet.robotics.rcx)
|
|
 | | Re: Power to RCX
|
|
(...) Utter nonsense until you destroy the controller itself. Remember, while the Lego motors can take a fairly substantial voltage without being destroyed, the same is not true of the motor controller within the RCX. There is a voltage limit for (...) (23 years ago, 14-Feb-02, to lugnet.robotics.rcx)
|
|
 | | Re: Palm IR to RCX
|
|
"Till Harbaum" <lego-robotics@crynwr.com> wrote in message news:200202131831.g1....uka.de... (...) <<snip>>. (...) The remote is a one way only messaging scheme. It sends a "standard" RCX message of opcode 0xD2 and two data bytes. The two data (...) (23 years ago, 14-Feb-02, to lugnet.robotics)
|
|
 | | RE: power source
|
|
Yeah, I used a multimeter and measured the 11.2V I'm going to go to my local electronic store and get all the parts (they have everything in stock) but why the 16v capacitor? -----Original Message----- From: Mathias Uhr [mailto:uhr@mathias.net] (...) (23 years ago, 14-Feb-02, to lugnet.robotics)
|
|
 | | Re: Lost my IR Tower
|
|
hi Peter, Why did you remove the IR diodes ? I think it's not necessary, or am I missing something. It would even be nicer, if also the IR-sensor could be left in place, but I don't know the Lego circuit. Stef Mientki (...) (23 years ago, 13-Feb-02, to lugnet.robotics)
|
|
 | | Re: Lost my IR Tower
|
|
Nice idea Peter !! I'll add it to my collection about the IR port of the RCX. At first I didnt see what your design could mean foe me, but .... This could be an alternative way to add "intelligent" sensors (for example through PIC or some other (...) (23 years ago, 13-Feb-02, to lugnet.robotics)
|
|
 | | Re: It came out too easily to be the first
|
|
(...) Austin Robot Group. Lego's are a SMALL part of what this group has been working on for the last 12-13 years. Just ask Mark Thorpe of Robot Wars fame or Mark Pauline of SRL fame (we helped put on the '97 show here in Austin). (URL) robots were (...) (23 years ago, 13-Feb-02, to lugnet.robotics)
|
|
 | | Re: power source
|
|
(...) What I meant when i said "unregulated" was a power supply without a 78xx in it. The power supply that I am using consists of a transformer, rectifier (4 diodes) and a 4700uf cap. This means that while it does give a clean voltage, that voltage (...) (23 years ago, 13-Feb-02, to lugnet.robotics)
|