To LUGNET HomepageTo LUGNET News HomepageTo LUGNET Guide Homepage
 Help on Searching
 
Post new message to lugnet.roboticsOpen lugnet.robotics in your NNTP NewsreaderTo LUGNET News Traffic PageSign In (Members)
 Robotics / 5433
5432  |  5434
Subject: 
Re: using nqc for first time
Newsgroups: 
lugnet.robotics
Date: 
Thu, 24 Jun 1999 18:51:37 GMT
Viewed: 
1383 times
  
In article <37717F24.AAA74617@earthlink.net>, kevcarl@earthlink.net wrote:

Dave Baum wrote:


Have you tried this with the modem port (instead of the printer port)?  It
shouldn't make a difference, but at this point almost anything is worth
trying.


Voila! Everything seems to work fine on the modem port! I just assumed
it would make no difference. Not only does nqc work, but my RoboLab
software now works also. I wonder why? I always thought that these two
ports were basically the same - I guess there must be differences.

My first guess would be that its a software issue and not hardware.  The
ports should be nearly identical hardware-wise (unless you have a geoport
enabled modem port).  It could be that something else (AppleTalk?) is
munging with the port.  I can look at the NQC code again, but its pretty
much straight from an Apple Tech Note on using the serial ports.

If I recall correctly, you also used the Mindstorms software under VPC.
Was this with the same cables as those used for nqc?


Yeah. these same cables work worked on the printer port under VPC. But
since the communications code for the Mindstorms software had to be
hacked in order to work in VPC, I'm not surprised if there are vast
differences in the way the serial ports are handled in VPC and in MacOS.
I know the Connectix people had to write their own drivers to make the
Mac printers, modems and the Palm Pilot accessible through VPC. Who
knows? But the important thing is everything seems to be working now.
Thanks for all your help!

I was thinking about buying a PCI card to add four serial ports to my
Mac. I can't wait to see what kind of a monkey wrench that throws into
all this :-)


Might not be a problem (for NQC).  I know someone already has used a PCI
serial port card with NQC - you just need to know the right name for the
I/O drivers.  Once you get the card let me know and I can talk you through
configuring NQC for it.

Dave

--
reply to: dbaum at enteract dot com



Message is in Reply To:
  Re: using nqc for first time
 
(...) Voila! Everything seems to work fine on the modem port! I just assumed it would make no difference. Not only does nqc work, but my RoboLab software now works also. I wonder why? I always thought that these two ports were basically the same - I (...) (25 years ago, 24-Jun-99, to lugnet.robotics)