  RE: LNP Repost
 
Very true, but lets try hard not to add any more bytes to the header. The smaller the better since the packets are probably pretty small. -Jake -----Original Message----- From: Ben Laurie [mailto:ben@algroup.co.uk] Sent: Saturday, April 17, 1999 (...) (25 years ago, 17-Apr-99, to lugnet.robotics.rcx.legos)
 
  RE: LNP Repost
 
Those are some really good points, but I am still concerned about the complexity and overhead of implementing IPC on the lego. Since resources are so limited it might just be easier to use shared memory and semaphores to communicate. On the other (...) (25 years ago, 17-Apr-99, to lugnet.robotics.rcx.legos)
 
  Linux Newbie
 
Here is a silly question, but you guys are the right ones to answer it... compliment I think :) I need to find a "What the hell is Linux" webpage. I _think_ it is a OS that is user developed, and is common on UNIX systems. I run windows 98 and (...) (25 years ago, 17-Apr-99, to lugnet.robotics.rcx.legos)
 
  Re: LNP Repost
 
(...) For IPC, each (unshared) connection would take 2 ports (src/dest), so 4 bits at least lets us have 7 IPCs (assuming port 0 is reserved as it is in Berkeley sockets, 8 if it is not). I could certainly see having need of more than 3 IPC (...) (25 years ago, 17-Apr-99, to lugnet.robotics.rcx.legos)
 
  Re: Rotation sensor bug found (maybe!)
 
(...) You've got a point here. What if we hardwire STATE_0_VALUE to the following? #define STATE_0_VALUE (ds_unscale(1023U)-RANGE_SIZE) Or, for a more general approach: #define MIN(a,b) (a<b?a:b) #define MAX(a,b) (a>b?a:b) #define STATE_VALUE(k) ( \ (...) (25 years ago, 17-Apr-99, to lugnet.robotics.rcx.legos)
 
  Rotation sensor bug found (maybe!)
 
I think I might have found a bug in the ds_rotation_handler (direct-sensor.c). The problem arises when the STATE_0_VALUE is checked using the IN_RANGE macro. As STATE_0_VALUE is 1023U<<6, which is about the max value for an unsigned, adding to it (...) (25 years ago, 17-Apr-99, to lugnet.robotics.rcx.legos)
 
  Re: LNP Repost
 
(...) Actually, no. On attempt 16, you reserve some more bits further down for the new version number :-) Cheers, Ben. -- (URL) grandfather once told me that there are two kinds of people: those who work and those who take the credit. He told me to (...) (25 years ago, 17-Apr-99, to lugnet.robotics.rcx.legos)
 
  Re: LNP Repost
 
(...) I'd prefer 11111b for broadcast, in keeping with TCP/IP. Cheers, Ben. -- (URL) grandfather once told me that there are two kinds of people: those who work and those who take the credit. He told me to try to be in the first group; there was (...) (25 years ago, 17-Apr-99, to lugnet.robotics.rcx.legos)
 
  Re: LNP Repost
 
I personally can't see needing more than about 7 tasks listening at one time anyway. Keep in mind that the resources on the lego are very very small. As far as reserving an address for IPC that would be fine. We could reserve 00000b for IPC and (...) (25 years ago, 17-Apr-99, to lugnet.robotics.rcx.legos)
 
  Re: LNP Repost
 
(...) I can see this. but it is starting to feel a little cramped on the ports, though. What functionality is port 0 reserved for? Actually, I was thinking of reserving a host address (such as 0x0) for IPC. I'd probably want to have more than 3 (...) (25 years ago, 16-Apr-99, to lugnet.robotics.rcx.legos)
 
  Rotation sensor help (some progress)
 
Again about my problems with legOS and the rotation sensor. First of all I checked the four values returned by both my two rotation sensor. They are different from the ones inside direct-sensor.c but anyway inside the specified range legOS: (...) (25 years ago, 16-Apr-99, to lugnet.robotics.rcx.legos)
 
  Re: legOS Network Protocol
 
I figured that out... Thanks... I am subscribed via email now! Much nicer... I am just too lazy to remeber to go check news groups. -Jake (...) (25 years ago, 16-Apr-99, to lugnet.robotics.rcx.legos)
 
  Re: legOS Network Protocol
 
Jacob S. Barrett <jsbarrett@acm.org> wrote in message news:3716681C.D5C8C6...acm.org... (...) You can subscribe to this newsgroup as a mailing list. I would prefer to see it on this group (or less thing to subscribe to) or to have lugnet make a new (...) (25 years ago, 16-Apr-99, to lugnet.robotics.rcx.legos)
 
  LNP Repost
 
I thought it might be good to repost this with some changes... Okay a little smaller... Only a 4 byte header... |0|1|2|3|4|5|6|7|0|1...3|4|5|6|7| ---...--- | 0xF | VER | TOADDR | PORT| FRADDR | PORT| PAYLOADLEN | ---...--- / PAYLOAD / ---...--- / (...) (25 years ago, 16-Apr-99, to lugnet.robotics.rcx.legos)
 
  Re: legOS Network Protocol
 
(...) I am not in position right now, time-wise, to contribute to the LNP, but I am very interested, and may have time to contribute soon. In the mean time, I'd like to keep up with the project. I don't know if you realize, Jacob, but if you prefer (...) (25 years ago, 15-Apr-99, to lugnet.robotics.rcx.legos)
 
  Re: legOS Network Protocol
 
This would almost have to be a UDP like protocol just because the RCX has such limited resources and the complexity of adding transmision control to the protocol would be nasty. I really hate news groups, I like having messages sent to me directly. (...) (25 years ago, 15-Apr-99, to lugnet.robotics.rcx.legos)
 
  Rotation sensor help
 
I need some help with legOS and rotation sensors. I compiled and downloaded the demo/rotation-sensor.c program. The behaviour I get on my RCX is not what I expected. When I turn the sensor clockwise, the LCD toggles between 0 and -1, while (...) (25 years ago, 15-Apr-99, to lugnet.robotics.rcx.legos)
 
  Re: legOS Network Protocol
 
(...) Sounds good. Does it provide a stream interface or datagrams only? My faulty memory suggests that it might be the latter. If the network implementation supports packet reassembly (packets larger than MTU), there may not be a need for a stream (...) (25 years ago, 14-Apr-99, to lugnet.robotics.rcx.legos)
 
  Re: legOS Network Protocol
 
(...) I too may be interested in this, although probably only the higher level stuff ie I'm not too sure how good I'd be at interfacing with the IR. Anyway, I had a look around and I found some references on a protocol layered on top of IP called (...) (25 years ago, 14-Apr-99, to lugnet.robotics.rcx.legos)
 
  Re: firmdl error
 
(...) [Luis sent me the .srec file so I could take a look at it.] The problem is the length of the first line of the srec file. The first line is 80 characters long, which is too long. The cryptic error message is because the line passed into the (...) (25 years ago, 14-Apr-99, to lugnet.robotics.rcx.legos)