To LUGNET HomepageTo LUGNET News HomepageTo LUGNET Guide Homepage
 Help on Searching
 
Post new message to lugnet.robotics.rcxOpen lugnet.robotics.rcx in your NNTP NewsreaderTo LUGNET News Traffic PageSign In (Members)
 Robotics / RCX / 2080 (-20)
  DCC for the RCX
 
Hello All, I've completed a new bit of firmware that enables the RCX to act as a DCC Command Station. For those who are not familiar, DCC (short for Digital Command Control) is a means of sending electrical signals over model railroad tracks to (...) (22 years ago, 28-May-03, to lugnet.robotics.rcx, lugnet.trains) !! 
 
  R: R: Transmitting a message from the RCX to the PC
 
A C++ OO framework that encapsulates the LASM bytecode of Lego has been developed inside a didactical project. The class spirit that maintains the communication with the RCX is the fundamental part of this framework. The source code of this class (...) (22 years ago, 26-May-03, to lugnet.robotics.rcx)
 
  Re: Remote control under linux
 
Oh chris I have a litle problem. I want to execute the program 1 and it stop when I stop to send the message Is there an other code to send to hand this progrma ? nanobapt (22 years ago, 25-May-03, to lugnet.robotics.rcx)
 
  Re: Transmitting a message from the RCX to the PC
 
Would it be possible to have two RCX's communicate back and forth with a single PC by using two Infrared towers? By enclosing one tower/RCX pair in a box you could isolate the RCX's from interrupting each other's communications. I'm guessing that (...) (22 years ago, 25-May-03, to lugnet.robotics.rcx)
 
  Re: R: Transmitting a message from the RCX to the PC
 
(...) Giuseppe, your attachment was discarded by the LUGNET server. Could you briefly summarize the information from the readme file that you think is relevant to this discussion? Thanks in advance! - Chris. (22 years ago, 23-May-03, to lugnet.robotics.rcx)
 
  Re: Remote control under linux
 
(...) Nice work! Glad to see a native Linux version of this. Quickly scanning your source code (no Linux machine to run it on today!) I notice that you send RCX opcodes in order to emulate the effect of each button on the remote. This is an (...) (22 years ago, 23-May-03, to lugnet.robotics.rcx)
 
  R: Transmitting a message from the RCX to the PC
 
Look at the material, it contains a readme file. this is just the top of the iceberg. If you are interested let me know. Giuseppe -----Messaggio Originale----- Da: "Steven lane" <steveroblane@aol.com> A: <lugnet.robotics.rcx...ugnet.com> Data invio: (...) (22 years ago, 23-May-03, to lugnet.robotics.rcx)
 
  Re: Transmitting a message from the RCX to the PC
 
(...) This is what I was wondering about. You have defined the core problem that needs solving (I was going to ask you to do that). So it seems we can have one PC to RCX link or multiple RCX's but not both, darn! (...) My initial idea/solution would (...) (22 years ago, 23-May-03, to lugnet.robotics.rcx)
 
  Remote control under linux
 
Like (URL) devellop a program to emulate the mindstorms remote controller under linux I'm using GTK, here is a snapshot : (URL) you want to have it download it here : (URL) compile it you have to install gtk-dev 2.0 and compile with this option : (...) (22 years ago, 23-May-03, to lugnet.robotics.rcx)  
 
  Re: Transmitting a message from the RCX to the PC
 
(...) This is a good technique for addressing messages to an individual RCX, and I've used it myself on many occasions. In this case, it is your RCX or NQC program on the 'bot that is "responding" or "not responding" either by taking action or (...) (22 years ago, 23-May-03, to lugnet.robotics.rcx)
 
  Re: Transmitting a message from the RCX to the PC
 
I'm posting this on behalf of John Donaldson who is having a problem with his emails bouncing, so this is his text verbatim. Why can't a mode where a two byte sequence is sent. The first byte is the bot address and the second byte is the data code. (...) (22 years ago, 22-May-03, to lugnet.robotics.rcx)
 
  Re: Transmitting a message from the RCX to the PC
 
(...) I am not sure if there is a way to disable the communications on the RCX when using the standard firmware. You could try putting an aluminum foil blinder around RCX No 2's IR transceiver, but I've found IR notoriously difficult to block since (...) (22 years ago, 22-May-03, to lugnet.robotics.rcx)
 
  Re: Transmitting a message from the RCX to the PC
 
(...) I'm not the originator of this thread but I am interested in the same problem. I'm intending to use MS visual c++ V4 spirt.ocx RIS 2.0 firmware and NQC (...) I do want to use two RCX's though. My plan is to have RCX No 2 send data to RCX No 1. (...) (22 years ago, 22-May-03, to lugnet.robotics.rcx)
 
  Re: Transmitting a message from the RCX to the PC
 
(...) The one-byte messages supported by the RCX are not generally designed to go from the RCX to the PC. They are intended to go from the PC to the RCX, or from one RCX to another. One reason for this is that the original RS-232 IR tower would not (...) (22 years ago, 22-May-03, to lugnet.robotics.rcx)
 
  BricxCC release 3.3.7.5
 
Version 3.3.7.5 fixes two bugs with the copy to clipboard function on the Analysis graph. It fixes the Clear Memory function so that it now clears all five program slots (it used to leave slot 1 untouched). It fixes form and component size issues (...) (22 years ago, 22-May-03, to lugnet.robotics.rcx.nqc, lugnet.robotics.rcx.legos, lugnet.robotics.rcx)
 
  Transmitting a message from the RCX to the PC
 
Hi, Can somebody help me out with what is involved in transmitting a message from the RCX to the PC. I have an application and I have tried to read the message from the RCX on the PC, but i am not getting the desired results. Thanks Michael (...) (22 years ago, 22-May-03, to lugnet.robotics.rcx)
 
  Re: R: Upgrade RCX?
 
Hi, the board is still under development, do far I dont have any PCB layout. All is done on a prototype board and not all comonents tested yet. A simple port of BrickOS is also not possible, because of the complete different structure of the µC. I (...) (22 years ago, 21-May-03, to lugnet.robotics.rcx.java, lugnet.robotics.rcx, lugnet.robotics.rcx.legos)
 
  Re: RCX packet format
 
Michael, It depends on what type of software you are running on the PC. If you are talking directly to the serial port (or USB port) on the PC side, then you don't need to adhere to any specific packet type, you can invent your own (if that's what (...) (22 years ago, 19-May-03, to lugnet.robotics.rcx)
 
  SoftWIRE Curriculum for MindStorms Programming
 
I just noticed that a former employer of mine, SoftWIRE, has made their MindStorms programming curriculum available for free download. SoftWIRE is a graphical programming extension for Visual Studio .NET that, among other things, I added programming (...) (22 years ago, 19-May-03, to lugnet.edu, lugnet.robotics.rcx) ! 
 
  R: Upgrade RCX?
 
I'm using Lego MindStorms for didactical laboratory at Politecnico di Torino. I'm interested in your project. I have two questions: Would it be difficult to reproduce in multiple copies your board? How do you solve the problem of porting the (...) (22 years ago, 17-May-03, to lugnet.robotics.rcx.java, lugnet.robotics.rcx, lugnet.robotics.rcx.legos)


Next Page:  5 more | 10 more | 20 more

Redisplay Messages:  All | Compact

©2005 LUGNET. All rights reserved. - hosted by steinbruch.info GbR