To LUGNET HomepageTo LUGNET News HomepageTo LUGNET Guide Homepage
 Help on Searching
 
Post new message to lugnet.roboticsOpen lugnet.robotics in your NNTP NewsreaderTo LUGNET News Traffic PageSign In (Members)
 Robotics / 3164
3163  |  3165
Subject: 
Re: DATALOG and C
Newsgroups: 
lugnet.robotics
Date: 
Sun, 24 Jan 1999 23:38:03 GMT
Viewed: 
1095 times
  
Brandon wrote in message <36AB8D74.B9D@sprynet.com>...
Michael Gasperi wrote:
The UploadDatalog and SetDatalog are Immediate Commands and
can not be included in an RCX program.

What do you mean by this?
Do you mean they can't be included in a program running on the RCX?
Yes

Or can't be included in a program running on the host PC?
No

The two commands are executed by the PC.  The PC sends something to the RCX
and then it does something.

It is not exactly datalogging, but you might want to use the VariableChange
OLE event.  Page 96 of the SDK.  With VariableChange and the SetEvent
function you can send values from the RCX as they are acquired.  It only
works with variable 0.



Message is in Reply To:
  Re: DATALOG and C
 
Michael Gasperi wrote: The UploadDatalog and SetDatalog are Immediate Commands and (...) What do you mean by this? Do you mean they can't be included in a program running on the RCX? Or can't be included in a program running on the host PC? (25 years ago, 24-Jan-99, to lugnet.robotics)