To LUGNET HomepageTo LUGNET News HomepageTo LUGNET Guide Homepage
 Help on Searching
 
Post new message to lugnet.roboticsOpen lugnet.robotics in your NNTP NewsreaderTo LUGNET News Traffic PageSign In (Members)
 Robotics / 14397
14396  |  14398
Subject: 
Re: IR tower problems
Newsgroups: 
lugnet.robotics
Date: 
Thu, 15 Feb 2001 23:01:06 GMT
Original-From: 
Steve Baker <sjbaker1@airmail.[saynotospam]net>
Reply-To: 
(sjbaker1@airmail)ihatespam(.net)
Viewed: 
1710 times
  
Miles Gentry wrote:
> 
> In lugnet.robotics, Ralph Hempel writes:
> > If you just buy a serial extension cable and plug it into your PC, you can
> > then plug anything you like in the other end of the cable. Plus you don't
> > have to crouch around behind the PC.
> [snip]
> My attempt failed when adding an extension cable 2 meters in length.  The
> computer reported a failure to communicate with the IR tower.   The total
> length of the two joined cables apparently exceeds the maximum length for IR
> Tower communication.  What maximum length of extension cable would you
> recommend?

There must be something terribly wrong if you couldn't get it to go
over a couple of meters.

RS-232's maximum cable length depends on the baud rate - at 9600, it's
good for about 500 meters IIRC.  The tower comms is about 1200? 2400?
You *should* be able to use a cable up to a kilometer in length...something
like that.

--
Steve Baker   HomeEmail: <sjbaker1@airmail.net>
              WorkEmail: <sjbaker@link.com>
              HomePage : http://web2.airmail.net/sjbaker1
              Projects : http://plib.sourceforge.net
                         http://tuxaqfh.sourceforge.net
                         http://tuxkart.sourceforge.net
                         http://prettypoly.sourceforge.net
                         http://freeglut.sourceforge.net



Message has 1 Reply:
  Re: IR tower problems
 
In lugnet.robotics, sjbaker1@airmail.net writes: [snip] (...) [snip] Strange. My attempts still fail with extension cables, but still work with 2.2 meter Lego cable only. Failed twice at total 4.2m when trying to add 2m extension cables. Test #1 (...) (26 years ago, 17-Feb-01, to lugnet.robotics)

Message is in Reply To:
  Re: IR tower problems
 
(...) [snip] My attempt failed when adding an extension cable 2 meters in length. The computer reported a failure to communicate with the IR tower. The total length of the two joined cables apparently exceeds the maximum length for IR Tower (...) (26 years ago, 15-Feb-01, to lugnet.robotics)