Re: Suggestions for new primitives: Flex-System hoses.
Newsgroups: 
lugnet.cad.dev
Date: 
Mon, 1 May 2000 16:03:48 GMT
Viewed: 
1913 times
  
Sounds like a good idea.  We should do a similar thing for the ribbed
hoses.

Steve

In lugnet.cad.dev, Fredrik Glöckner wrote:

> I think it would be useful to have new primitives for the flex system
> hoses.  I'm talking about the 8 LDU thick flexible straw-like elements
> which are used as decorative elements or as hoses for the Flex-System.
> 
> What we would need are two elements:
> 
>  One open ended hose which can be scaled to fit the desired length, or
>  used as many segments to model a curved, bent hose.
> 
>  One end segment which is closed.
> 
> Since the end of the hoses are often stuck into a "hole", the ends are
> often straight, while the rest of the hose is curved.  It would
> therefore be a good idea to let the end segments have "some" length (eg
> 1 LDU) so that they can be scaled to have the desired straight length
> inside the "hole".
> 
> Here are my suggestions, the names may very well be changed, obviously:
> 
> >   0 Technic Flex-System Hose with One End Closed
> >   0 Name: HOSEEND.DAT
> > 
> >    1 16 0 0 0 2 0 0 0 1 0 0 0 2 4-4CYLI.DAT
> >    1 16 0 0 0 4 0 0 0 1 0 0 0 4 4-4CYLI.DAT
> >    1 16 0 1 0 4 0 0 0 1 0 0 0 4 4-4EDGE.DAT
> >    1 16 0 1 0 2 0 0 0 1 0 0 0 2 4-4EDGE.DAT
> >    1 16 0 1 0 2 0 0 0 1 0 0 0 2 RING1.DAT
> >   0
> 
> 
> >   0 Technic Flex-System Hose Segment Open Ended
> >   0 Name: HOSESEG.DAT
> > 
> >    1 16 0 0 0 2 0 0 0 1 0 0 0 2 4-4CYLI.DAT
> >    1 16 0 0 0 4 0 0 0 1 0 0 0 4 4-4CYLI.DAT
> >   0
> > 



Message has 1 Reply:
  Re: Suggestions for new primitives: Flex-System hoses.
 
(...) That would be great! I have worked a bit on them myself. Here's what I have done so far: (URL) used two sub parts for the ribbed hose: end and segment parts. Look for "RIBD-END.DAT" and "RIBD-SEG.DAT". These are somewhat modified from Mark R. (...) (26 years ago, 1-May-00, to lugnet.cad.dev)

Message is in Reply To:
  Suggestions for new primitives: Flex-System hoses.
 
I think it would be useful to have new primitives for the flex system hoses. I'm talking about the 8 LDU thick flexible straw-like elements which are used as decorative elements or as hoses for the Flex-System. What we would need are two elements: (...) (26 years ago, 28-Apr-00, to lugnet.cad.dev)