Subject:
|
Re: LPub 4 Status
|
Newsgroups:
|
lugnet.cad.dev
|
Date:
|
Fri, 7 Mar 2008 04:44:39 GMT
|
Viewed:
|
9077 times
|
| |
| |
In lugnet.cad.dev, Travis Cobbs wrote:
> In lugnet.cad.dev, Kevin L. Clague wrote:
> > In lugnet.cad.dev, Travis Cobbs wrote:
> > > In lugnet.cad.dev, Kevin L. Clague wrote:
> > > > One new metacommand
> > > >
> > > > 0 !LPUB RESOLUTION <value> (DPI|DPM|DPMM)
> > > >
> > > > defines the resolution.
> > >
> > > Shouldn't that be:
> > >
> > > 0 !LPUB RESOLUTION <value> (DPI|DPCM)
> > >
> > > Based on this:
> > >
> > > > The values in the LDraw file are either in inches, or centimeters, depending on
> > > > what resolution says. Sorry, no meter or millimeter expressions, just inches or
> > > > centimeter. No unit string like "INCHES" "IN" or "CM". The units are implied
> > > > by resolution.
> > >
> > > --Travis
> >
> > When I looked around on the net I saw references to DPM and DPMM.... I didn't
> > see DPCM.... it does make complete sense to use DPCM, but I wasn't sure people
> > would think its a standard name.
>
> I'd say that DPM or DPMM make perfect sense. The thing is, your description
> said that units are all in CM or IN, and that M and MM aren't supported. And
> yet, you force the user to specify which units to use in either IN, M, or MM.
> That seems very inconsistent.
>
> --Travis
I'm actually can provide all of the above and to the math, I just don't want to
have units expressed in individual meta commands. I ony want one unit and to
have it expressed in the resolution meta command. So I could even have DPDM.....
(decimeters? ;^)
Kevin
|
|
Message has 2 Replies: | | Re: LPub 4 Status
|
| (...) I agree. It was inconsistent. I've provided DPM, DPCM, DPMM, and the values specified in meta commands are scaled appropriately. (17 years ago, 7-Mar-08, to lugnet.cad.dev)
| | | Re: LPub 4 Status
|
| (...) I agree. It was inconsistent. I've provided DPM, DPCM, DPMM, and the values specified in meta commands are scaled appropriately. (17 years ago, 7-Mar-08, to lugnet.cad.dev)
|
Message is in Reply To:
| | Re: LPub 4 Status
|
| (...) I'd say that DPM or DPMM make perfect sense. The thing is, your description said that units are all in CM or IN, and that M and MM aren't supported. And yet, you force the user to specify which units to use in either IN, M, or MM. That seems (...) (17 years ago, 6-Mar-08, to lugnet.cad.dev)
|
81 Messages in This Thread:
- Entire Thread on One Page:
- Nested:
All | Brief | Compact | Dots
Linear:
All | Brief | Compact
This Message and its Replies on One Page:
- Nested:
All | Brief | Compact | Dots
Linear:
All | Brief | Compact
|
|
|
|