In lugnet.cad.dev, Travis Cobbs wrote:
In lugnet.cad.dev, Kevin L. Clague wrote:
In lugnet.cad.dev, Travis Cobbs wrote:
In lugnet.cad.dev, Kevin L. Clague wrote:
One new metacommand

0 !LPUB RESOLUTION <value> (DPI|DPM|DPMM)

defines the resolution.

Shouldn't that be:

0 !LPUB RESOLUTION <value> (DPI|DPCM)

Based on this:

The values in the LDraw file are either in inches, or centimeters, depending on
what resolution says.  Sorry, no meter or millimeter expressions, just inches or
centimeter.  No unit string like "INCHES" "IN" or "CM".  The units are implied
by resolution.

--Travis

When I looked around on the net I saw references to DPM and DPMM.... I didn't
see DPCM.... it does make complete sense to use DPCM, but I wasn't sure people
would think its a standard name.

I'd say that DPM or DPMM make perfect sense.  The thing is, your description
said that units are all in CM or IN, and that M and MM aren't supported.  And
yet, you force the user to specify which units to use in either IN, M, or MM.
That seems very inconsistent.

--Travis

I'm actually can provide all of the above and to the math, I just don't want to
have units expressed in individual meta commands.  I ony want one unit and to
have it expressed in the resolution meta command. So I could even have DPDM.....
(decimeters? ;^)

Kevin



Message has 2 Replies:
  Re: LPub 4 Status
 
(...) I agree. It was inconsistent. I've provided DPM, DPCM, DPMM, and the values specified in meta commands are scaled appropriately. (17 years ago, 7-Mar-08, to lugnet.cad.dev)
  Re: LPub 4 Status
 
(...) I agree. It was inconsistent. I've provided DPM, DPCM, DPMM, and the values specified in meta commands are scaled appropriately. (17 years ago, 7-Mar-08, to lugnet.cad.dev)

Message is in Reply To:
  Re: LPub 4 Status
 
(...) I'd say that DPM or DPMM make perfect sense. The thing is, your description said that units are all in CM or IN, and that M and MM aren't supported. And yet, you force the user to specify which units to use in either IN, M, or MM. That seems (...) (17 years ago, 6-Mar-08, to lugnet.cad.dev)