To LUGNET HomepageTo LUGNET News HomepageTo LUGNET Guide Homepage
 Help on Searching
 
Post new message to lugnet.robotics.rcxOpen lugnet.robotics.rcx in your NNTP NewsreaderTo LUGNET News Traffic PageSign In (Members)
 Robotics / RCX / 1460
1459  |  1461
Subject: 
Re: GP2D12 IR sensor RCX active sensor interface?
Newsgroups: 
lugnet.robotics.rcx
Date: 
Tue, 9 Oct 2001 16:13:18 GMT
Viewed: 
1861 times
  
FYI - I just noticed in the component specs from Sharp that the GP2D12
(and GP2D15 for that matter) have a built-in voltage regulator.
See
http://www.sharp.co.jp/ecg/opto/products/pdf/optical_sd/optical_sd/gp2d12.pdf

So is an external regulator a necessary precaution? Just curious...

- Gareth



Message has 1 Reply:
  Re: GP2D12 IR sensor RCX active sensor interface?
 
(...) Hi Gareth, maybe you don't need an external regulator ?!?! But, the specs also say that rating of supply voltage is "-0.3 to +7V". Do you know what happens to the sharp if supply voltage rises above +7V ??? (the mux has a supply voltage of +9V (...) (23 years ago, 9-Oct-01, to lugnet.robotics.rcx)

Message is in Reply To:
  Re: GP2D12 IR sensor RCX active sensor interface?
 
(...) Hi Gareth, I guess the three wire solution won't work. (Not tested it myself) The Sharp GP2D12 have a current consumption of about 35mA-50 mA (at 5V) !!!! Michael Gasperi mentioned that an input of the RCX only give about 15mA. ((URL) techno (...) (23 years ago, 8-Oct-01, to lugnet.robotics.rcx)

7 Messages in This Thread:

Entire Thread on One Page:
Nested:  All | Brief | Compact | Dots
Linear:  All | Brief | Compact

This Message and its Replies on One Page:
Nested:  All | Brief | Compact | Dots
Linear:  All | Brief | Compact
    

Custom Search

©2005 LUGNET. All rights reserved. - hosted by steinbruch.info GbR