Hello Kurt, I want show you three possiblities for alternative power supplies. 1. Take 2 sets of 6 NiMH accus or 2 * 6 NiCd accus to have one set inside the rcx an one set in the charger. This would be a very simple way to solve your problem. 2. The (...) (24 years ago, 27-Apr-00, to lugnet.robotics.rcx)
 
  Re: lnptest gives collision errors. Sigh...
 
(...) I guess there is no hope. I found a long thread here with someone else who had a collision problem . I applied the patch to transmitter.c mentioned in that thread with the same result. I downloaded lnpd.static from arthurdent. Same result. I (...) (24 years ago, 27-Apr-00, to lugnet.robotics.rcx.legos)
 
  Re: Duplex Comms with RCX
 
(...) I actually prefer the "junk" solution to a hardware hack. (24 years ago, 27-Apr-00, to lugnet.robotics, lugnet.robotics.tele, lugnet.robotics.rcx.nqc)
 
  Re: Duplex Comms with RCX
 
(...) It seems to me that, given the current hardware, the choices are: send junk or let the tower go dead. My thinking is that if you send junk and trample something, so be it; the tower would have gone dead anyways, forcing you to lose whatever it (...) (24 years ago, 27-Apr-00, to lugnet.robotics, lugnet.robotics.tele, lugnet.robotics.rcx.nqc)
 
  Re: Duplex Comms with RCX
 
(...) Fair enough. It's too bad it doesn't have an always-on mode. (...) Definitely agreed. I'll be patient. (24 years ago, 27-Apr-00, to lugnet.robotics, lugnet.robotics.tele, lugnet.robotics.rcx.nqc)
 
  Re: Duplex Comms with RCX
 
(...) I just haven't found a non-intrusive method for keeping the tower alive. I hate transmitting garbage every few seconds and possibly trampling incoming data. I'm also not sure this is a very good long-term solution. Really a general purpose (...) (24 years ago, 26-Apr-00, to lugnet.robotics, lugnet.robotics.tele, lugnet.robotics.rcx.nqc)
 
  Re: Duplex Comms with RCX
 
(...) Not that there's any pressure or anything. :) (24 years ago, 26-Apr-00, to lugnet.robotics, lugnet.robotics.tele, lugnet.robotics.rcx.nqc)
 
  Alternative Power Supplies
 
I have an RIS 1.5 set, which doesn't have the power connector. I seem to run through a set of batteries in 1-2 weeks, which will eventually get very expensive. What ways are there, other than using rechargable batteries, to supply power to the RCX (...) (24 years ago, 26-Apr-00, to lugnet.robotics.rcx)
 
  Re: Duplex Comms with RCX
 
(...) Dave had mentioned making a listen mode w/ keep-alive in a future version of nqc. But I don't think he's gotten around to that yet. (24 years ago, 26-Apr-00, to lugnet.robotics, lugnet.robotics.tele, lugnet.robotics.rcx.nqc)
 
  Re: Duplex Comms with RCX
 
(...) Yes. Note that it is only half-duplex. You probably expected that. (...) The biggest issue you might run into is the fact that the IR tower used by the PC times out if it doesn't transmit anything for a few seconds. Unless you have constant (...) (24 years ago, 26-Apr-00, to lugnet.robotics, lugnet.robotics.tele, lugnet.robotics.rcx.nqc)