To LUGNET HomepageTo LUGNET News HomepageTo LUGNET Guide Homepage
 Help on Searching
 
Post new message to lugnet.roboticsOpen lugnet.robotics in your NNTP NewsreaderTo LUGNET News Traffic PageSign In (Members)
 Robotics / 13884
13883  |  13885
Subject: 
Re: Interfacing Sharp's GP2D02 Distance Sensor to the RCX
Newsgroups: 
lugnet.robotics
Date: 
Fri, 12 Jan 2001 13:57:41 GMT
Viewed: 
1899 times
  
In lugnet.robotics, Ram Meenakshisundaram writes:
> Adding a power pack to the interface isnt really a problem.  How would
> you connect it if we use an external power supply?  Can we just use
> Michael's GPAI at http://www.plazaearth.com/usr/gasperi/gpa.htm?  Sorry
> about the basic questions, I am a software engineer not an electrical
> engineer...

Makes no sense for use with GP2D02 (uses serial protocol).

Using the more general purpose analog interface (the one with the opamp)
should work well with GP2D12 I think (I'm also no electrical engineer).
You can adjust the output then (Sharp 0.6V - 3.1V).

Perhaps you should add a voltage regulator to this curcuit (like LM78L05 /
5V 0.1A max.) to drive the Sharp. (it needs 4.5V - 5.5V)

I'll test it when I get my Sharps (GP2D12) back (i lent them to a friend of
mine and get them back in some weeks).

Rainer



Message is in Reply To:
  Re: Interfacing Sharp's GP2D02 Distance Sensor to the RCX
 
Adding a power pack to the interface isnt really a problem. How would you connect it if we use an external power supply? Can we just use Michael's GPAI at (URL) Sorry about the basic questions, I am a software engineer not an electrical engineer... (...) (26 years ago, 11-Jan-01, to lugnet.robotics)

15 Messages in This Thread:







Entire Thread on One Page:
Nested:  All | Brief | Compact | Dots
Linear:  All | Brief | Compact
    

©2005 LUGNET. All rights reserved. - hosted by steinbruch.info GbR