 | | Re: DATALOG and C
|
|
(...) I see your point about UploadDatalog, as the tower falls asleep and the PC won't hear the RCX shouting. But SetDatalog seems to work in a program just fine, to set the size of the datalog buffer. BTW, what is the maximum size for the datalog, (...) (28 years ago, 25-Jan-99, to lugnet.robotics)
|
| |
 | | RE: DATALOG and C
|
|
To find the current maximum size of the datalog, get a MemMap. There is a pointer to the start of the datalog area and also a pointer to the top of the memory area. Subtract these two values for the current maximum size of the datalog. -Brian (...) (28 years ago, 25-Jan-99, to lugnet.robotics)
|
| |
 | | Re: slightly off topic: two questions (one of them for EE types)
|
|
(...) Two things... there are two styles of pots avalible one is an "audio" pot and the other is linear. The audio pots are usually marked with a 'A'. Since the audio pots are primarily designed for adjusting the volume level, they actually have a (...) (28 years ago, 25-Jan-99, to lugnet.robotics)
|
| |
 | | Re: Thoughts on Turning
|
|
(...) yup, and the 2nd design on there (my dad's design) doesn't require 5 length axles anyway. i knew that i could get 5length axles, i just didn't have any (they are a bit rare still) and cut up a 10 length axles. i can remember doing the same (...) (28 years ago, 25-Jan-99, to lugnet.robotics)
|
| |
 | | HB download
|
|
Hi Everyone: My handy boards were working fine all this time but suddenly they seem to have developed a problem. The boards do not show the interactive C welcome message. I tried downloading the pcode file a number of times. That file downloads (...) (28 years ago, 25-Jan-99, to lugnet.robotics.handyboard)
|
| |
 | | IrDA anyone ?
|
|
I wonder would it be possible to communicate with the RCX using an IrDA compliant IR port such as ones on Notebooks or H/PC. I know someone had done it with his HP palmtop. Is IrDA standard IR port operating within the bandwidth of the RCX IR port ? (...) (28 years ago, 25-Jan-99, to lugnet.robotics)
|
| |
 | | Re: DATALOG and C
|
|
(...) SetDatalog is listed in the SDK page 91 as an Immediate Command. If that is true then, if you put the command in with some downloadable RCX instructions, it does whatever it does right then and is not actually sent with the RCX program. (...) (28 years ago, 25-Jan-99, to lugnet.robotics)
|
| |
 | | Re: DATALOG and C
|
|
(...) I believe that the maximum size of the datalog is 2033 entries, minus whatever you need for program data. If you want to figure this out dynamically from the PC, get the memory map after downloading all programs to the RCX. The maximum datalog (...) (28 years ago, 25-Jan-99, to lugnet.robotics)
|
| |
 | | Using motors without a power source.
|
|
I'm new to this group so I don't know if this idea has been mentioned but here it is: First, I connect the two motors in the MindStorms kit together with a wire and nothing else. Below is a crude ASCII art representation: ***...*** ***...*** * * (...) (28 years ago, 25-Jan-99, to lugnet.robotics)
|
| |
 | | Re: Using motors without a power source.
|
|
(...) In this case one motor is being used as a generator and the other as a motor, correct? You aren't powering both motors. I think its neat, but don't understand the use of it in the context of 4wd. The differential is much smaller then two (...) (28 years ago, 25-Jan-99, to lugnet.robotics)
|