 Robotics / *29564 (-10)
  Re: bushing (bush) question
 
In lugnet.robotics, Bram Lambrecht writes: [...] (...) I think this is correct. I once built the "Aliens" type walker, (URL) . I used Type 2 originally and found that after the thing would walk a few meters one of the legs would pop off. Didn't have (...) (25 years ago, 24-Aug-01, to lugnet.robotics, lugnet.technic)
 
  Re: Lego Dacta Control Lab software
 
Looks like only PC is available on that site. Could you give me a site for the Mac version? Thanks for your time, (...) (25 years ago, 24-Aug-01, to lugnet.robotics)
 
  RE: bushing (bush) question
 
(...) Type 2 is newer, probably because the Type 1's were too hard to take off the axle. I've noticed that most of my loose Type 1's have a hairline fracture on one side. (...) All the parts with teeth were essentially replaced with functional (...) (25 years ago, 24-Aug-01, to lugnet.robotics, lugnet.technic)
 
  Re: How to communication between RCXs without PC?
 
You know I had finished my control program in NQC, it is not so simple, but I need to control LEGO Train in smooth speed, NQC is limitation, so I want to use legOS for one of RCX, could you give me some hints for sending/receiving NQC style message (...) (25 years ago, 24-Aug-01, to lugnet.robotics.rcx.legos)
 
  Re: How to communication between RCXs without PC?
 
(...) As far as I know, it is not possible to communicate between legOS and NQC using LNP. I think it would be possible to directly drive the IR port from your own code to send and recieve NQC-style communications, but the ability isn't built into (...) (25 years ago, 24-Aug-01, to lugnet.robotics.rcx.legos)
 
  Re: How to communication between RCXs without PC?
 
Thanks a lot, Michael. Is it possible to commucate between two RCXs and one uses legOS and another one uses NQC? I will read them, but could you give me a simplest sample here? (...) (25 years ago, 24-Aug-01, to lugnet.robotics.rcx.legos)
 
  Re: How to communication between RCXs without PC?
 
(...) Yes. Read the HOWTO section on LNP, which stands for legOS Networking Protocol. If you have any questions the HOWTO doesn't answer, feel free to ask here. (25 years ago, 24-Aug-01, to lugnet.robotics.rcx.legos)
 
  How to communication between RCXs without PC?
 
I am thinking to convert NQC program to legOS, but I am not sure how to communicate between RCXs without PC (similar as SendMessage() and Message() in NQC), does anyone have experience? Zhengrong (...) (25 years ago, 24-Aug-01, to lugnet.robotics.rcx.legos)
 
  Re: bushing (bush) question
 
(...) Based on my experience, out of over 200 Type 1's that I own, only a few have ever split in half. Having recently acquired a used 8880 supercar (which uses Type 2's), I now have over 20 split Type 2's, and that number keeps increasing with use. (...) (25 years ago, 24-Aug-01, to lugnet.robotics, lugnet.technic)
 
  Re: Power inlet to RCX 1.5?
 
(...) But what sort of Voltage and Amperage do you use with that connection? Coz, with me it won't work very well with a couple of adapters putting out 6 to 12 Volts (max. 1.25 A). Grtz., Remko (25 years ago, 24-Aug-01, to lugnet.robotics)