 | | Re: bushing (bush) question
|
|
In lugnet.robotics, Bram Lambrecht writes: [...] (...) I think this is correct. I once built the "Aliens" type walker, (URL) . I used Type 2 originally and found that after the thing would walk a few meters one of the legs would pop off. Didn't have (...) (25 years ago, 24-Aug-01, to lugnet.robotics, lugnet.technic)
|
| |
 | | Re: Lego Dacta Control Lab software
|
|
Looks like only PC is available on that site. Could you give me a site for the Mac version? Thanks for your time, (...) (25 years ago, 24-Aug-01, to lugnet.robotics)
|
| |
 | | RE: bushing (bush) question
|
|
(...) Type 2 is newer, probably because the Type 1's were too hard to take off the axle. I've noticed that most of my loose Type 1's have a hairline fracture on one side. (...) All the parts with teeth were essentially replaced with functional (...) (25 years ago, 24-Aug-01, to lugnet.robotics, lugnet.technic)
|
| |
 | | Re: How to communication between RCXs without PC?
|
|
You know I had finished my control program in NQC, it is not so simple, but I need to control LEGO Train in smooth speed, NQC is limitation, so I want to use legOS for one of RCX, could you give me some hints for sending/receiving NQC style message (...) (25 years ago, 24-Aug-01, to lugnet.robotics.rcx.legos)
|
| |
 | | Re: How to communication between RCXs without PC?
|
|
(...) As far as I know, it is not possible to communicate between legOS and NQC using LNP. I think it would be possible to directly drive the IR port from your own code to send and recieve NQC-style communications, but the ability isn't built into (...) (25 years ago, 24-Aug-01, to lugnet.robotics.rcx.legos)
|
| |
 | | Re: How to communication between RCXs without PC?
|
|
Thanks a lot, Michael. Is it possible to commucate between two RCXs and one uses legOS and another one uses NQC? I will read them, but could you give me a simplest sample here? (...) (25 years ago, 24-Aug-01, to lugnet.robotics.rcx.legos)
|
| |
 | | Re: How to communication between RCXs without PC?
|
|
(...) Yes. Read the HOWTO section on LNP, which stands for legOS Networking Protocol. If you have any questions the HOWTO doesn't answer, feel free to ask here. (25 years ago, 24-Aug-01, to lugnet.robotics.rcx.legos)
|
| |
 | | How to communication between RCXs without PC?
|
|
I am thinking to convert NQC program to legOS, but I am not sure how to communicate between RCXs without PC (similar as SendMessage() and Message() in NQC), does anyone have experience? Zhengrong (...) (25 years ago, 24-Aug-01, to lugnet.robotics.rcx.legos)
|
| |
 | | Re: bushing (bush) question
|
|
(...) Based on my experience, out of over 200 Type 1's that I own, only a few have ever split in half. Having recently acquired a used 8880 supercar (which uses Type 2's), I now have over 20 split Type 2's, and that number keeps increasing with use. (...) (25 years ago, 24-Aug-01, to lugnet.robotics, lugnet.technic)
|
| |
 | | Re: Power inlet to RCX 1.5?
|
|
(...) But what sort of Voltage and Amperage do you use with that connection? Coz, with me it won't work very well with a couple of adapters putting out 6 to 12 Volts (max. 1.25 A). Grtz., Remko (25 years ago, 24-Aug-01, to lugnet.robotics)
|