To LUGNET HomepageTo LUGNET News HomepageTo LUGNET Guide Homepage
 Help on Searching
 
Post new message to lugnet.technicOpen lugnet.technic in your NNTP NewsreaderTo LUGNET News Traffic PageSign In (Members)
 Technic / 4274
4273  |  4275
Subject: 
RE: RCX & Cybermaster (VLL comms and MicroScout)
Newsgroups: 
lugnet.technic, lugnet.robotics
Date: 
Thu, 15 Mar 2001 10:59:14 GMT
Reply-To: 
<marco@soporcel.!AvoidSpam!pt>
Viewed: 
1111 times
  
Hi Chris,

Do a search for "CM-RCX Comm" thread, in lugnet.robotics :)

That's (still) my main current project.

It works. It's possible to make a CM and a RCX communicate with each other
through "eletric" (or light but I didn't test the input through light, yet)
connection.

I was working on a custom version of the standard LEGO VLL serial comms
protocol. My "SlowVLL" is 9 times slower than standard VLL, but the main
thing is: it works.
I created SlowVLL protocol because the CyberMaster doesn't support
FastTimer(), (RCX2 firmware does), so, for now, it's impossible to do input
on a CyberMaster at a standard VLL data rate (but Standard VLL output to
RCX2/MicroScout/CodePilot is possible).

After doing some tests on "SlowVLL" input, I was going to finish my lib with
both SlowVLL input/output and Standard VLL input(RCX2)/output, *BUT* I
encountered a problem with memory capacity on the CyberMaster :( ...for now,
the current (complete) version of my NQC lib needs more memory than
CyberMAster has to offer.

On top of that, my spare (hobby) time is equal to zero :(

I'll post future info on lugnet.robotics under the "CM-RCX Comm" thread :)

mc.

PS: OH! I just got the #9754 Dark Side Developer Kit set, so now I'll have a
MicroScout to do some Standard VLL tests and calibration of my lib's output
routines :)
By the way, the 4 legged walker WALKS PERFECTLY ! Great LEGO design job.
...now, I'll just have to think a way to make it turn :>

-----Original Message-----
From: news-gateway@lugnet.com
[mailto:news-gateway@lugnet.com]On Behalf
Of Chris Fenter
Sent: quinta-feira, 15 de Março de 2001 00:30
To: lugnet.technic@lugnet.com
Subject: RCX & Cybermaster


Has anyone tried (successfully, or not...) to create working
models or systems using both of these items together?

I'm guessing that I could use a mechanical feedback circuit
(like 8868 alt. model / 8479) to trigger the RCX from the
actions of the Cybermaster, and vice-versa, but I haven't had
the chance to try it yet. Is there any good way of making
them interact electronically? (other than just linking the
same touch sensor to inputs on both to trigger different actions, say)

Thx,
Chris.


--
MIME ATTACHMENTS DISCARDED:

1.  Content-Type: text/html;
    charset=so-8859-1"
    Content-Transfer-Encoding: quoted-printable
    Content-Length: 924




Message has 1 Reply:
  Re: RCX & Cybermaster (VLL comms and MicroScout)
 
(...) Thx, Marco. I'm investigating! btw, Do you mean that they communicate through a standard lead attached to sensor inputs, say, or some other electrical connection? Interesting that the CM can't communicate at speed, but the MS & CP will. I'd (...) (24 years ago, 20-Mar-01, to lugnet.technic, lugnet.robotics)

Message is in Reply To:
  RCX & Cybermaster
 
Has anyone tried (successfully, or not...) to create working models or systems using both of these items together? I'm guessing that I could use a mechanical feedback circuit (like 8868 alt. model / 8479) to trigger the RCX from the actions of the (...) (24 years ago, 15-Mar-01, to lugnet.technic)

6 Messages in This Thread:


Entire Thread on One Page:
Nested:  All | Brief | Compact | Dots