 | | Re: DDK - What use are they / lower prices seen
|
|
(...) You can have some fun with the Micro Scout if you have the Scout from Robotics Discovery Set (9735). Some of the Scout's built-in programs emit Visible Light Link codes from its LED (output port 3) to trigger built-in programs in the Micro (...) (25 years ago, 26-Feb-01, to lugnet.robotics, lugnet.robotics.vll, lugnet.robotics.microscout, lugnet.robotics.scout)
|
| |
 | | Re: Downloading byte codes
|
|
(...) Try (URL) but you will have better results avoiding byte codes and using NCQ2.3b1 instead. (25 years ago, 26-Feb-01, to lugnet.robotics.scout)
|
| |
 | | Downloading byte codes
|
|
do any of you guys know how to download byte codes to the scout? I know the codes but I cant figure out how to send the to the scout....is there a program that downloads the codes? or do you use NQC? Alex (25 years ago, 16-Feb-01, to lugnet.robotics.scout)
|
| |
 | | Re: Problem
|
|
(...) be (...) never mind I got it to work..... I like you WinNQC program it is a lot faster to use. can you tell me how you get the remote control thingy to work? I cant click on it right now.....do you have to be doing somthing special to use it? (...) (25 years ago, 16-Feb-01, to lugnet.robotics.scout)
|
| |
 | | Re: Problem
|
|
I was used 2.2, I haven't test it in 2.3, you can try 2.2, I think it should be ok! Zhengrong (...) (25 years ago, 16-Feb-01, to lugnet.robotics.scout)
|
| |
 | | Re: legOS
|
|
(...) SetSensor() doesn't work at all on the Scout. By definition, SENSOR_3 is the light sensor and configured in a somewhat unusual mode (it reads 0, 1, or 2). Its been a long time since I've worked on the Scout. I think you set the light (...) (25 years ago, 16-Feb-01, to lugnet.robotics.scout)
|
| |
 | | Re: legOS
|
|
(...) How would you use the built in light sensor like this? "SetSensor(SENSOR_3,...R_LIGHT);" or somting like that? Oh and can you use the temprature sensor on the scout? Alex (25 years ago, 15-Feb-01, to lugnet.robotics.scout)
|
| |
 | | Re: Problem
|
|
(...) When I try to compile the program there are 13 compilation errors like "Undefined Variable 'LIGHT'" and "Undefined variable 'right'" and stuff like that, all undefined variables. What version of NQC do you have? I have version 2.3 a, mabey I (...) (25 years ago, 15-Feb-01, to lugnet.robotics.scout)
|
| |
 | | Re: Problem
|
|
What do you mean? Please tell me more detail? I think it is no problem as I am using it. Zhengrong (...) (25 years ago, 15-Feb-01, to lugnet.robotics.scout)
|
| |
 | | Re: legOS
|
|
(...) Most of the programs out there are for the RCX, not the Scout. Where possible, the APIs are the same between the two, but there are a lot of unavoidable problems. For example, the RCX has configurable sensor ports, so the program must make (...) (25 years ago, 15-Feb-01, to lugnet.robotics.scout)
|