  RE: Is there a compatible h8 assembler for forth words?
 
(...) No there is not. That being said, it's pretty easy to write one...if you have the time. I fiddled around with it a bit and then gave up since the GNU tools worked pretty quick. It was strictly a time/value exchange. From bitter experience, (...) (24 years ago, 19-May-00, to lugnet.robotics.rcx.pbforth)
 
  Re: Is there a compatible h8 assembler for forth words?
 
(...) I don't think this is clear. I ment an assembler written in pbforth that can create assembler defined words in the RCX (24 years ago, 19-May-00, to lugnet.robotics.rcx.pbforth)
 
  Is there a compatible h8 assembler for forth words?
 
I asked this once before but in the middle of an unrelated email so the question got lost. (24 years ago, 19-May-00, to lugnet.robotics.rcx.pbforth)
 
  RE: hforth register usage
 
(...) Right. If you look at the beginning of h8hforth.asm, I've abstracted the actual register names so I could move them around....here's the snippet from the file... ; The H8/300 Forth machine register usage has to be closely intertwined with ; (...) (24 years ago, 19-May-00, to lugnet.robotics.rcx.pbforth)
 
  hforth register usage
 
Ralph, I'm trying to add an assembler word and trying to deduce register. usage. Could you verify for me please. It looks like the top cell on the stack is actually a register (r6). The second cell on the stack is pointer to by r7. This means that (...) (24 years ago, 19-May-00, to lugnet.robotics.rcx.pbforth)
 
  Re: Help with Terminal Emulator
 
(...) At first look, I thought this looked like a baud rate problem. But with Ralph's program (at least on my machine), you can't really screw up....the baud rate is set in rcxutil.tcl, and overrides whatever you do in the control panel "ports" (...) (24 years ago, 18-May-00, to lugnet.robotics.rcx.pbforth)
 
  Re: Help with Terminal Emulator
 
(...) A little more information please. Describe the sequence. Start by taking a battery out for at least 10 second so you know the RCX is in a known state. Then verify that the config file is pointed to the right serial port. Then try to download (...) (24 years ago, 18-May-00, to lugnet.robotics.rcx.pbforth)
 
  More info on pbForth GUI
 
Thanks to Jeffrey Hazen, Steve Morris, Paul Addison, Mario Ferrari, and others, I can happily confirm that the new GUI works on Windows NT and Windows 2K. There are still some issues under Linux... I've added more info to the default GUI home page (...) (24 years ago, 18-May-00, to lugnet.robotics.rcx.pbforth, lugnet.robotics)
 
  Help with Terminal Emulator
 
I'm just getting started using pbForth, and I'm having trouble with the terminal emulator echoing garbage on the screen with almost every key stroke. I've tried all of the suggested terminal emulators with the same results, including hyperterminal, (...) (24 years ago, 17-May-00, to lugnet.robotics.rcx.pbforth)
 
  Re: New pbForth GUI
 
(...) need (...) the (...) Maybe...I'll keep you informed :-) In the meanwhile I tested your GUI on a Win2000 machine (version 5.0, build 2195). Same procedure, same positive result. Mario (24 years ago, 17-May-00, to lugnet.robotics.rcx.pbforth)