To LUGNET HomepageTo LUGNET News HomepageTo LUGNET Guide Homepage
 Help on Searching
 
Post new message to lugnet.robotics.rcx.nqcOpen lugnet.robotics.rcx.nqc in your NNTP NewsreaderTo LUGNET News Traffic PageSign In (Members)
 Robotics / RCX / NQC / *557 (-10)
  Re: Duplex Comms with RCX
 
(...) Dave had mentioned making a listen mode w/ keep-alive in a future version of nqc. But I don't think he's gotten around to that yet. (25 years ago, 26-Apr-00, to lugnet.robotics, lugnet.robotics.tele, lugnet.robotics.rcx.nqc)
 
  Re: Duplex Comms with RCX
 
(...) Yes. Note that it is only half-duplex. You probably expected that. (...) The biggest issue you might run into is the fact that the IR tower used by the PC times out if it doesn't transmit anything for a few seconds. Unless you have constant (...) (25 years ago, 26-Apr-00, to lugnet.robotics, lugnet.robotics.tele, lugnet.robotics.rcx.nqc)
 
  Re: Duplex Comms with RCX
 
"James Hammond" <jsh@it-innovation.soton.ac.uk> wrote in message news:3906A2E6.6A40E0...n.ac.uk... (...) Yes it can. There is a standard RCX opcode for sending single byte messages, and you can always use multiple of these commands for more complex (...) (25 years ago, 26-Apr-00, to lugnet.robotics, lugnet.robotics.tele, lugnet.robotics.rcx.nqc)
 
  Re: Duplex Comms with RCX
 
It appears Roblab 2.0 would also be an alternative for your project. Robolab has two different direct modes to control the RCX, one of which is using a remote connection like the Internet. Depending on your direct control requirements, you may want (...) (25 years ago, 26-Apr-00, to lugnet.robotics, lugnet.robotics.tele, lugnet.robotics.rcx.nqc)
 
  RCX2 API
 
I've put together a NQC API file that allows you to use some of the RCX2 features. I don't no whether anyone else has already done this but here is mine. This is unofficial so is unsupported. All question should go to the group, not Dave or myself. (...) (25 years ago, 26-Apr-00, to lugnet.robotics.rcx.nqc)  
 
  RCX2 API
 
I've put together a NQC API file that allows you to use some of the RCX2 features. I don't no whether anyone else has already done this but here is mine. This is unofficial so is unsupported. All question should go to the group, not Dave or myself. (...) (25 years ago, 26-Apr-00, to lugnet.robotics.rcx.nqc)
 
  Duplex Comms with RCX
 
Hi I am sure this has been done many times before, but I am having trouble confirming information. I wish to purchase the RIS 1.5. But before I do I need to be sure that I can communicate with a running program on the RCX and that the RCX can (...) (25 years ago, 26-Apr-00, to lugnet.robotics, lugnet.robotics.tele, lugnet.robotics.rcx.nqc)
 
  Re: Q: Determining state of outputs
 
It works fine. Thanks for your help! Oliver (25 years ago, 25-Apr-00, to lugnet.robotics.rcx.nqc)
 
  Re: RCX2: ViewSourceValue Help
 
(...) asm statements are just followed by a comma-separated list of fields enclosed in braces. In general, each field is evaluated at compile time and the resulting value is truncated to 8 bits. The exception is the & operator. The &x syntax is used (...) (25 years ago, 24-Apr-00, to lugnet.robotics.rcx.nqc)
 
  RCX2: ViewSourceValue Help
 
Hi, I'm back after a break from Lego. (I had exams). I've been playing around with RCX2 firmware and want to use the new ViewSourceValue command. What is the correct asm for this. So far I've got this by guessing and looking at RCX2.NQH #define (...) (25 years ago, 24-Apr-00, to lugnet.robotics.rcx.nqc)


Next Page:  5 more | 10 more | 20 more

Redisplay Messages:  All | Compact

©2005 LUGNET. All rights reserved. - hosted by steinbruch.info GbR