| | Re: can't dll with brickOS 2.6.10
|
|
(...) Dear Ben I have the same problem. But i checked version 0.2.6 till 0.2.6.10 and i got the same problem with all versions. (only vers 0.2.5 and earlier works) . I have testes with WIN2000 and WIN98. cygwin Vers is B20 and i use the old (...) (22 years ago, 22-Apr-03, to lugnet.robotics.rcx.legos)
|
|
| | Re: LNP and DLL
|
|
(...) Oh it's normal :) Soft use the library liblnp to connect to tower with lnpd. And lnpd block the acess to the tower ! You need then to download your program with a program like dllx or dll which is include in the application folder of lnpd (...) (22 years ago, 21-Apr-03, to lugnet.robotics.rcx.legos)
|
|
| | LNP and DLL
|
|
Hi there. I'm running cygwin (because I just have the usb tower) well I want to use the addressing mode of lnp. Ok I edit the file boot/config.h of the kernel and have this: #define CONF_LNP #define CONF_LNP_FAST #define CONF_LNP_HOSTADDR 0x20 (...) (22 years ago, 20-Apr-03, to lugnet.robotics.rcx.legos)
|
|
| | Re: LNPD and cygwin
|
|
Nop, actually what I'd like to find out, is if there's some way to make the usb tower work (either on cygwin or linux) for lnpd Thanks in advance, if anyone has the answer CL "nanobapt" <nanobapt@wanadoo.fr> escribió en el mensaje (...) (22 years ago, 20-Apr-03, to lugnet.robotics.rcx.legos)
|
|
| | Re: LNPD and cygwin
|
|
(...) does lnpd work with usb tower under linux ? nanobapt (22 years ago, 17-Apr-03, to lugnet.robotics.rcx.legos)
|
|
| | LNPD and cygwin
|
|
Sorry if this message is duplicated, but I got an error when publishing and untin now I don't see it published. Hi all, I have the USB tower so by now (because I have a project for the university, and not too much time) I've to use cygwin. Well (...) (22 years ago, 17-Apr-03, to lugnet.robotics.rcx.legos)
|
|
| | LNPD and Cygwin
|
|
Hi all, I have the USB tower so by now (because I have a project for the university, and not too much time) I've to use cygwin. Well everthing is running fine, but I came with this question: Is is possible to install LNPD (as a deamon) the same way (...) (22 years ago, 17-Apr-03, to lugnet.robotics.rcx.legos)
|
|
| | addressing bricks
|
|
Hi everyone, I was wondering if anyone could tell me how to address RCX bricks, using LNP. I have been looking at examples of code on lnp for ages now. Any help would be appreciated. Thanks a lot Andrew ___...___ Hotmail messages direct to your (...) (22 years ago, 13-Apr-03, to lugnet.robotics.rcx.legos)
|
|
| | Re: Can an input be configured as an output?
|
|
Hi Vik, An input has a 10K pull-up resistor to 5V in it. When nothing is connected to the input the A/D converter will return a value of about 1023 (which represents 5V). If you short the input (make sure it's in passive mode), you will get a value (...) (22 years ago, 11-Apr-03, to lugnet.robotics.rcx.legos)
|
|
| | Can an input be configured as an output?
|
|
Hi, Im still learning legos (brickOS) and my friend asked me whether an input could be configured as an output? Also, i have seen several robots using 2 RCX, all connected together using wires running from 1 input to anothers output...how does this (...) (22 years ago, 10-Apr-03, to lugnet.robotics.rcx.legos)
|