  RE: disable LNP
 
(...) Doesn't the H8/300 have a mode where you can scan up to 4 channels at once? Ralph (21 years ago, 12-Oct-03, to lugnet.robotics.rcx.legos)
 
  Re: disable LNP
 
(...) Mark is correct: I made the following two changes which will cause the sensors to be polled at 1KHz: in systime.c; added "bset #0x5,@_AD_CSR:8"; extern void clock_handler(void); ... sys_nohigh: mov.w #0x5a06,r6 ; reset wd timer to 6 mov.w (...) (21 years ago, 12-Oct-03, to lugnet.robotics.rcx.legos)
 
  Re: disable LNP
 
(...) Sorry, nothing has made it to an official release. I think Joseph Woolley has some code where he reduced the sample rate to 1KHz (I think). You might try contacting him about it. Mark (21 years ago, 11-Oct-03, to lugnet.robotics.rcx.legos)
 
  Re: disable LNP
 
(...) Have the changes from the above thread been implemented in a release of BrickOS, yet? (reduced sensor sample rate) I need to D/L a new release, but I don't want to rush, because I know I'll have to make changes to some of my existing code. (...) (21 years ago, 10-Oct-03, to lugnet.robotics.rcx.legos)
 
  Re: disable LNP
 
(...) Steve, If no IR traffic (of any kind) is occurring, then there is very little overhead associated with LNP being active. In any event, this trivial amount of overhead (in systime.c) can't be disabled. What you really need to be concerned about (...) (21 years ago, 10-Oct-03, to lugnet.robotics.rcx.legos)