| | Re: The PRGM key
|
| I dont know if it makes any difference, but I always put the destination before the name of the program. Ex: dll -p1 hello.lx Steve (...) (23 years ago, 8-Apr-02, to lugnet.robotics.rcx.legos)
| | | | Re: The PRGM key
|
| Sorry, no. That's the one difference; it no longer says error deleting program and I don't get any errors when downloading to the RCX. I always use firmdl3 -s because using just firmdl3 on its own never works for me. I still have the problem that (...) (23 years ago, 8-Apr-02, to lugnet.robotics.rcx.legos)
| | | | Re: The PRGM key
|
| After making the change, do you still get "Error deleting program"? or other errors while downloading the program? Your assumption is correct, it will only switch to a program slot if there is a valid program there. I had problems sending programs (...) (23 years ago, 8-Apr-02, to lugnet.robotics.rcx.legos)
| | | | Re: The PRGM key
|
| I just tried this and it has no effect. By the way, I'm using Cygwin B20 under Windows 98 with a com port IR thing, and LegOS 0.2.5. The same thing happened using WinLegOS and 0.2.3. Pressing the PRGM key has no effect in any situation - I assume it (...) (23 years ago, 7-Apr-02, to lugnet.robotics.rcx.legos)
| | | | Re: The PRGM key
|
| I had similar problems when using legOS with CONF_TM defined in boot/config.h What I found was that the lnp handler was not getting enough processing time and was missing some data at times. Try the following fix and let me know if it helps. If so, (...) (23 years ago, 7-Apr-02, to lugnet.robotics.rcx.legos)
| |