  Re: IR Proximity Detection Problem
 
Maybe the ambient light is too high ? in that case you can decrease visible light sensitivity as well as shielding detector from red LED light using this method : (URL) (only hope that this doesn't offend your "Lego purity" sense ;o) Philo (...) (22 years ago, 16-Jan-03, to lugnet.robotics.rcx)
 
  IR Proximity Detection Problem
 
I have tried to get proximity dectection via RCX emitting IR (SendMessage/NQC) and Light Sensor (mounted on top of the RCX's IR unit). But the raw values seemed to be the same with/without emitting IR. Average value was 725. Went up to 800 (black (...) (22 years ago, 16-Jan-03, to lugnet.robotics.rcx)
 
  VisionXperiment 1.0a1 Announcement
 
Hi All, I've uploaded a new application called VisionXperiment. Currently is is for MacOS X Only. Inspired by Vision Command, it allows your computer to respond to movement, color or light as seen by a Quicktime compatible camera. Currently the (...) (22 years ago, 11-Jan-03, to lugnet.robotics.rcx, lugnet.robotics.rcx.nqc)
 
  Re: RCX simulation
 
(...) (22 years ago, 4-Jan-03, to lugnet.robotics.rcx, lugnet.robotics.rcx.nqc, lugnet.robotics)
 
  RCX simulation
 
hi All, does anyone has experience with this RCX simulation tool ? Stef Mientki (22 years ago, 4-Jan-03, to lugnet.robotics.rcx, lugnet.robotics.rcx.nqc, lugnet.robotics)
 
  Re: RCX remote and Spybotics
 
I have noticed that they do interfer - mostly just 'blocking' signals from one or another. I haven't done any experimenting with changing frequencies on the spybots or tried to work around tis problem. I would still get a remote for the RCX - it (...) (22 years ago, 2-Jan-03, to lugnet.robotics.spybotics, lugnet.robotics.rcx)
 
  Re: RCX remote and Spybotics
 
Happy New Year! (again) "Mark Ferris" <markdf2001@yahoo.com> schrieb im Newsbeitrag news:dpg41vcgltkjmnk...4ax.com... (...) A lot of infrared "in the air" certainly conflicts, because there are no IR-channels. A pair LED and transistor work in a (...) (22 years ago, 1-Jan-03, to lugnet.robotics.spybotics, lugnet.robotics.rcx)
 
  RCX remote and Spybotics
 
Will the RCX remote control conflict with the IR signals from the Spybotics controller? I don't have a remote control, but I'd like to get one for my RCX so I can build my own style bot to compete with my kids, but I want to make sure my remote will (...) (22 years ago, 1-Jan-03, to lugnet.robotics.spybotics, lugnet.robotics.rcx)
 
  Re: RCX/Spybotics/Scout communication
 
(...) Spybotics uses a new IR protocol for communication between Spybotics devices, but the IR is also has user-configurable and can send RCX-style messages. Here is a sample program that sends messages from Spybotics to an RCX (or Scout): (URL) (...) (22 years ago, 26-Dec-02, to lugnet.robotics.spybotics, lugnet.robotics.rcx, lugnet.robotics.scout)
 
  Re: RCX/Spybotics/Scout communication
 
(...) With the latest release of Brixcc, you have the ability to control the spybot. I sent commands to the spybot from Bricxx, but havent' gotten to the point of actually sending commands from the RCX to the Spybot--been a little busy lately. That (...) (22 years ago, 24-Dec-02, to lugnet.robotics.spybotics, lugnet.robotics.rcx, lugnet.robotics.scout)
 
  Re: RCX/Spybotics/Scout communication
 
(...) I'm no expert here, but I hate to see questions go unanswered. I believe you can use the same NQC commands to send messages to and from the spybot as used in the standard RCX. (22 years ago, 24-Dec-02, to lugnet.robotics.spybotics, lugnet.robotics.rcx, lugnet.robotics.scout)
 
  RCX/Spybotics/Scout communication
 
Having read the messages in the various newsgoups, I must admit I'm a little puzzled. I've seen a lot of discussion about IR communication, but I don't think I have a straight answer. I have an RCX, a Scout, and some Spybotics under the Christmas (...) (22 years ago, 23-Dec-02, to lugnet.robotics.spybotics, lugnet.robotics.rcx, lugnet.robotics.scout)
 
  Re: New Version of leJOS
 
(...) (URL) (22 years ago, 20-Dec-02, to lugnet.robotics.rcx)
 
  RE: Firmware download troubles
 
The size of the firmware isn't going past the 0xcc00 boundary, is it? The firmware in the RCX only does a sum on the bytes up to 0xCBFF in the downloaded firmware, as far as I recall... Cheers, Ralph (22 years ago, 13-Dec-02, to lugnet.robotics.rcx)
 
  Re: Firmware download troubles
 
(...) The problem he's describing, if it's the same one I have, is independant of the position, direction, and power level of the tower. It seems to have something to do with BrixCC itself. The only thing I find puzzling is that Matt (the other Matt (...) (22 years ago, 13-Dec-02, to lugnet.robotics.rcx)
 
  Re: Firmware download troubles
 
(...) It's funny that you should bring this up - I've had exactly the same problems with several RCX's and downloading firmware from BrixCC. The only solution I've been able to find is to download the firmware using the RIS2.0 software and then (...) (22 years ago, 13-Dec-02, to lugnet.robotics.rcx)
 
  Re: Firmware download troubles
 
(...) Look at Edit/Preferences. On the General tab is a checkbox labeled "Use fast mode when downloading firmware" You can uncheck that option to use normal speed firmware downloads via BricxCC. John Hansen (URL) (22 years ago, 10-Dec-02, to lugnet.robotics.rcx)
 
  Re: Firmware download troubles
 
The low buzz tone is an error generated by the ROM firmware for failure condition detected as part of the "unlock firmware" opcode. There are two causes of this. [1] ROM software calculates a checksum value of the downloaded firmware and this (...) (22 years ago, 10-Dec-02, to lugnet.robotics.rcx)
 
  Re: Firmware download troubles
 
(...) ... (...) Dick and others, Thanks - this helped. What I did to solve this was run the NCQ command-line download at "normal" speed. This worked the first time. Interestingly, I am not sure that the Bricx (v3.3) download was running quad speed (...) (22 years ago, 10-Dec-02, to lugnet.robotics.rcx)
 
  Re: Firmware download troubles
 
A likely explanation for your downloading problem is the following. Standard Lego software uses 2400 baud data rate and a protocol that sends "double" bytes. The "double" byte is that each data byte is followed by its complement. Alternative (...) (22 years ago, 10-Dec-02, to lugnet.robotics.rcx)