 Robotics / RCX / *3335 (-10)
  legOS doesn't work under NT?
 
I've been using legOS for Windows (Vamos-Wentworth's distribution) both on Windows 95 and Windows 98. Due to some reasons, I'll have to use a NT computer from now on (I'm the administrator). I installed everything, even the long filename support (...) (24 years ago, 5-Oct-00, to lugnet.robotics.rcx.legos)
 
  Re: Is Extreme Creatures Good? (WAS: Re: US S@H Specials, Sep 20 - Sep 26, 2000)
 
(...) i'll (...) Not in my opinion, just a random collection of additional parts. There is an inventory at: (URL) I didn't buy the set, so maybe owners of the set would have a contrary opinion. Kerry (24 years ago, 5-Oct-00, to lugnet.market.shopping, lugnet.robotics.rcx, lugnet.robotics, lugnet.technic)
 
  Re: The datalog
 
(...) If only the RCX could read it's own data... Dean -- Coin-Op's For Sale!: (URL) Lego Workshop: (URL) Lego Club: (URL) (24 years ago, 5-Oct-00, to lugnet.robotics.rcx.nqc)
 
  Re: The datalog
 
(...) numbers. It can only log timers, sensors, variables, and the system watch. When a value is logged, its source is also logged. For example, AddToDatalog(Timer(1)) adds the current value of Timer 1 to the log and also stores that this entry came (...) (24 years ago, 5-Oct-00, to lugnet.robotics.rcx.nqc)
 
  Re: Sharp GP2D05 Infrared Ranger and the RCX
 
Hey, my GP2D12 just showed up. I ordered it from Acroname. It comes with a nice little booklet with details on how to rig it, and it even has some Handyboard code and interface info. I have test equipment in my lab too. I'll plug it into a power (...) (24 years ago, 4-Oct-00, to lugnet.robotics.rcx)
 
  Visual J++?
 
Has anyone used the OCX with Visual J++? Have any examples? -ben (24 years ago, 4-Oct-00, to lugnet.robotics.rcx.java, lugnet.robotics.rcx)
 
  Re: The datalog
 
BTW, what does the datalog *store*? Numbers? Events? Anything? And what good is it for (besides the methods we've disscussed earlier)? --Tobias (...) (24 years ago, 4-Oct-00, to lugnet.robotics.rcx.nqc)
 
  Re: IRPD sensors and LegOS (long)
 
OK, the IRPD rover just smarter. I had an error in the comments in the previously posted version, references in the initial comments about the Right Side Motor being hooked up to Output B were incorrect, it is actually hooked up to Output C. This (...) (24 years ago, 4-Oct-00, to lugnet.robotics.rcx.legos)
 
  Re: Dave Baum's scanbot w/ bumper?
 
(...) The problem is subtle. Scanbot (at least scanbot2.nqc) assumes that the drive motors are always running. It only alters their direction during steering. In your code you call OnFor(), which turns on the motors, waits a specified amount of (...) (24 years ago, 4-Oct-00, to lugnet.robotics.rcx)
 
  Re: The datalog
 
(...) Each call to AddToDatalog() uses up one "point". Each point takes up 3 bytes of memory: a 1-byte code for the source of point (sensor, timer, etc), then a 2-byte value. 123456 is too big to fit into the log. This would either generate a (...) (24 years ago, 4-Oct-00, to lugnet.robotics.rcx.nqc)