To LUGNET HomepageTo LUGNET News HomepageTo LUGNET Guide Homepage
 Help on Searching
 
Post new message to lugnet.robotics.rcxOpen lugnet.robotics.rcx in your NNTP NewsreaderTo LUGNET News Traffic PageSign In (Members)
 Robotics / RCX / *3325 (-10)
  Re: Scout poweroff time out?
 
(...) thanks. Comments are always welcome....that's not saying that I'll implement everything that anyone suggests, but I certainly appreciate the feedback. NQC wouldn't have gotten this far without the suggestions of the user community. Dave (24 years ago, 4-Oct-00, to lugnet.robotics.rcx.nqc, lugnet.robotics.scout)
 
  Re: The datalog
 
(...) Dave, I have a question about the datalog. In the manual you state that the createdatalog function creates a datalog of x many points. How much is a point? Is that how many unique entries can be made or an overall 'byte' amount? Is a value (...) (24 years ago, 3-Oct-00, to lugnet.robotics.rcx.nqc)
 
  Re: Scout poweroff time out?
 
(...) Yes, I'll try to do that when I have some time... (...) That's not too bad... heh heh. I'm just shocked at how little RAM there is for programing... Maybe the 'way' I program is memory intensive. I can see an art to programing the scout (...) (24 years ago, 3-Oct-00, to lugnet.robotics.rcx.nqc, lugnet.robotics.scout)
 
  Re: Sharp GP2D05 Infrared Ranger and the RCX
 
"Ram Meenakshisundaram" <rmeenaks@olf.com> wrote in message news:39DA076E.906020...olf.com... (...) Now how did I miss that! Now the only problem would be the power supply current. Like Ralph said, 33mA is right at the upper limit for a LEGO (...) (24 years ago, 3-Oct-00, to lugnet.robotics.rcx)
 
  Re: Sharp GP2D05 Infrared Ranger and the RCX
 
Hi, (...) (24 years ago, 3-Oct-00, to lugnet.robotics.rcx)
 
  Re: Sharp GP2D05 Infrared Ranger and the RCX
 
"Ralf Krause" <rkra@gmx.de> wrote in message news:B5FFBD90.545%rk...@gmx.de... (...) Yes the GP2D12 looks like the one to use, but I've never been able to find it. I bought some GP2D05s to play with a few years ago. They require an input control (...) (24 years ago, 3-Oct-00, to lugnet.robotics.rcx)
 
  Re: Sharp GP2D05 Infrared Ranger and the RCX
 
Ooh, you're right. This seems to be too much for battery powered models. Has anybody a better idea? I want to have a sensor with gives a linear (?) signal corresponding to a distance. For an 1-bit boolean signal I saw a plan in elektor 9/2000 (...) (24 years ago, 3-Oct-00, to lugnet.robotics.rcx)
 
  RE: Sharp GP2D05 Infrared Ranger and the RCX
 
(...) Ralf, If I remember correctly, these sensors draw about 30 mA, which is the limit for a powered sensor for the RCX. You may need to add an additional battery to supply the current.... Cheers, Ralph Hempel - P.Eng ---...--- Check out pbFORTH (...) (24 years ago, 3-Oct-00, to lugnet.robotics.rcx)
 
  Sharp GP2D05 Infrared Ranger and the RCX
 
Hi, this seems to be a very good idea for a new RCX sensor. Reading the Sharp data sheets for their infrared distance sensors I want to write some facts about. They have 4 different sensors for measuring distances from 10 to 80 cm. The differences (...) (24 years ago, 3-Oct-00, to lugnet.robotics.rcx)
 
  Re: 0.2.4 API
 
I can put one up as a tarball or .zip file- pick which output format you'd prefer. Luis (...) ---...--- "It's clear to us that Microsoft isn't the competition anymore. They are our environment." WordPerfect manager, talking about Word ---...--- (24 years ago, 3-Oct-00, to lugnet.robotics.rcx.legos)