To LUGNET HomepageTo LUGNET News HomepageTo LUGNET Guide Homepage
 Help on Searching
 
Post new message to lugnet.robotics.handyboardOpen lugnet.robotics.handyboard in your NNTP NewsreaderTo LUGNET News Traffic PageSign In (Members)
 Robotics / Handy Board / *6959 (-10)
  Re: IRPD
 
Kalyan, Both Marvin Green and Dennis Clark have IRPD kits (fairly cheap) that IMO are much better than the Lynxmotion unit (I have all three). (2 URLs) you get either Marvin's or Dennis' IRPD kit, I can send you PIC source code for either board that (...) (25 years ago, 16-Nov-99, to lugnet.robotics.handyboard)
 
  Re: IRPD
 
(...) I have a PIC based design on my web page: (URL) that will work with any micro. I have parts description and PIC source as well as a crude board layout graphic. This one is fully automated with a left/right/both sensing capability. I also have (...) (25 years ago, 16-Nov-99, to lugnet.robotics.handyboard)
 
  Re: IRPD
 
If you check (URL) you will find IRPD's with very narrow detection zones. Those are good for many applications. If you need one with wide coverage just for obstacle avoidance, check (URL) One or the other of those sites should work for you. Gary (...) (25 years ago, 16-Nov-99, to lugnet.robotics.handyboard)
 
  Re: HandyBoard Charging
 
no, to do the battery run-down test, you must not have it plugged in! otherwise you'd just be powering it from the adapter, and you'd never run out of juice. so, the steps are: 1. bootload your HB with pcode_hb.s19. you should see the Interactive C (...) (25 years ago, 16-Nov-99, to lugnet.robotics.handyboard)
 
  Re: HandyBoard Charging
 
Okay, I'll try it. Do I need to have the DC adapter plugged in to the (...) th (...) the (...) bei (...) pow (...) off (...) a (...) (25 years ago, 16-Nov-99, to lugnet.robotics.handyboard)
 
  Re: HandyBoard Charging
 
Danny, Since you imply that your battery does not take any charge at all, it sounds to me as though your problem is: (1) fuse F1 is open, or (2) a cell in your battery pack is open, or (3) one of the battery wires or its associated PCB land is open. (...) (25 years ago, 16-Nov-99, to lugnet.robotics.handyboard)
 
  IRPD
 
Hi, Can somebody point me some web pages for an Infrared Proximity Detector/sensor (IRPD) for the HandyBoard? Thanks Kalyan Kalyan Mulampaka Software Engineer e Information Services ___...___ Ph#: (770) 698 4436 (O) (678) 320 0783 (R) (25 years ago, 16-Nov-99, to lugnet.robotics.handyboard)
 
  Re: HandyBoard Charging
 
ok, you have the stock adapter. like i said, sometimes the batt does get fully charged and then not enough current flows in trickle-charge to light the LED. but that's normal, so it doesn't sound like there is actually a problem. a simple way to (...) (25 years ago, 16-Nov-99, to lugnet.robotics.handyboard)
 
  Re: HandyBoard Charging
 
Well I bought an assembled board from Gleason Research and I've been using the DC adapter that came with the board. The charging leds light up only when the Handyboard on? Is there something special I need to do to run the board on batteries? Is (...) (25 years ago, 16-Nov-99, to lugnet.robotics.handyboard)
 
  Re: HandyBoard Charging
 
do you have the recommended 12v, 500 ma DC adapter? if not, that explains it. if so, sometimes when the batt is fully charged, you don't get much in trickle charge mode and the light is off. but usually you should see the light being lit dimly. are (...) (25 years ago, 16-Nov-99, to lugnet.robotics.handyboard)