Fredrik Glöckner schrieb in Nachricht ...
"Anders Isaksson" <isaksson.etuna@REMOVEebox.tninet.se> writes:

With current monitoring, You can always be sure to stop before the motor • is
overloaded. You have to test a little for finding the correct limit • though.

And what would you say the current limit is?  I believe Andy Bower used
a limit of 95.  Would that apply to your case as well?

Fredrik

I did this stall detection too, testing it first with the truck and the fork
lifter with a loaded container. I had a current somewhere around 110mA when
the truck starts to fall over (heavy load!). I defined 100mA to be the
limit, as it´s not very fast to monitor the current through VB (timer and
polling),


Joerg



Message is in Reply To:
  Re: CM: MotorCurrent
 
(...) And what would you say the current limit is? I believe Andy Bower used a limit of 95. Would that apply to your case as well? Fredrik (25 years ago, 3-Jan-99, to lugnet.robotics)