Subject:
|
Re: CM: MotorCurrent
|
Newsgroups:
|
lugnet.robotics
|
Date:
|
Sun, 3 Jan 1999 18:16:38 GMT
|
Viewed:
|
1661 times
|
| |
| |
Fredrik Glöckner schrieb in Nachricht ...
> "Anders Isaksson" <isaksson.etuna@REMOVEebox.tninet.se> writes:
>
> > With current monitoring, You can always be sure to stop before the motor is
> > overloaded. You have to test a little for finding the correct limit though.
>
> And what would you say the current limit is? I believe Andy Bower used
> a limit of 95. Would that apply to your case as well?
>
> Fredrik
I did this stall detection too, testing it first with the truck and the fork
lifter with a loaded container. I had a current somewhere around 110mA when
the truck starts to fall over (heavy load!). I defined 100mA to be the
limit, as it´s not very fast to monitor the current through VB (timer and
polling),
Joerg
|
|