To LUGNET HomepageTo LUGNET News HomepageTo LUGNET Guide Homepage
 Help on Searching
 
Post new message to lugnet.roboticsOpen lugnet.robotics in your NNTP NewsreaderTo LUGNET News Traffic PageSign In (Members)
 Robotics / *5041 (+10)
  Re: Lugnet not accepting mail
 
(...) LUGnet, by the way, is a private network and is about as spam-proof as the mailing list is by itself anyway. (28 years ago, 9-Nov-98, to lugnet.robotics)
 
  Re: Solar-powered RCX?
 
(...) No, there is no way to tell as far as I know. I believe the choice of power source is done by circuitry, not logic. I do believe that the external power supply is used in preference to the batteries, but this might not really be the case - you (...) (28 years ago, 9-Nov-98, to lugnet.robotics)
 
  Re: Solar-powered RCX?
 
Though I can't remember the specific source, I did read just recently that the RCX will always use the external power supply (instead of the batteries) when it is plugged in. (If you plan to have it sitting turned on for long periods of time, (...) (28 years ago, 9-Nov-98, to lugnet.robotics)
 
  Re: Mindstorms: Submarine and Turbo Command
 
unsuscribe (28 years ago, 9-Nov-98, to lugnet.robotics)
 
  IR output connection
 
Hi All: With a lot of help from you all , I am finally able to send out a modulated signal from one HB which the other can recognize. :) Now I am trying out obstacle avoidance using the IR. I tried to use the standard ir_detect() function with the (...) (28 years ago, 9-Nov-98, to lugnet.robotics.handyboard)
 
  Subtasks quitting before completing
 
I saw some posts during the last three days about subtasks quitting before completing. I never saw a solution, so I will re-ask the question. If my robot triggers a touch sensor and before it completes all of the commands in that group of commands (...) (28 years ago, 9-Nov-98, to lugnet.robotics)
 
  Re: Spirit.ocx manual
 
Marshall Williams wrote in message <01BE0BB7.9F1AB180.M...tt.net>... (...) You may want to check out: (URL) Brok Visit LEGO ON MY MIND: (URL) section: (URL) (28 years ago, 9-Nov-98, to lugnet.robotics)
 
  Re: Subtasks quitting before completing
 
(...) The confusion is because only instantiation of each stack can be active at a time. If you start a stack that is already running, that stack stops, then restarts. The rule for conflicting signals is that the last one set has precedence. So if (...) (28 years ago, 9-Nov-98, to lugnet.robotics)
 
  Re: Subtasks quitting before completing
 
(...) This weekend I built a 4x4 rover with two front bumper sensors. I was faced with the problem of both sensors triggering at the same time. My fix was to set the counter to 1 and add a stack controller to check the counter before turning the (...) (28 years ago, 9-Nov-98, to lugnet.robotics)
 
  Firmware: IR transmission demystified
 
IR transmission was pretty tough to get at. Carrier frequency was the final key - there are no crystals to create the IR carrier, so the processor has to provide it. It turns out that 8-bit t1 output is used for just that purpose. Guess I'll have to (...) (28 years ago, 9-Nov-98, to lugnet.robotics)