Nice to be appreciated :-) Running the command 'strip -s *.exe' for each directory containing .exe files reclaims considerable disc space, by removing dubugging information which is embedded in the .exes. P.S. I did briefly experiment with a mingw (...) (25 years ago, 21-Jul-01, to lugnet.robotics.rcx.legos)
 
  Fix for remote patch
 
The remote patch on the sourceforge website is slightly broken on Win32. (The necessary code changes have been made in a Linux only section, but the Win32 bit is untouched. The problen is util/rcxtty.c, which does not set the correct (odd) parity (...) (25 years ago, 21-Jul-01, to lugnet.robotics.rcx.legos)
 
  LegOS, WIN98 & Cygwin 1.3.2
 
Hello, Well after a week of head beating, cursing, downloads and chicken waving AND a great deal of help from Max Bowsher (this last bit was actually the most useful :-) I finally have legOS up and running with the above setup. Had I followed Max's (...) (25 years ago, 21-Jul-01, to lugnet.robotics.rcx.legos)
 
  Re: Maximum sample rate (turn rate) for rotation sensor
 
Dave and Luis, Thank you both for the information. I'm big admirer of the work you've done for the RCX community. (...) I see. (60/0.003)/16 = 1250 And if you were worried about the Sampling Theorem you would divide that in half just to be sure.. (...) (25 years ago, 21-Jul-01, to lugnet.robotics.rcx)
 
  Re: Mystery Part
 
I bow down to you, Bob! Many thanks for solving this mystery. (...) (25 years ago, 21-Jul-01, to lugnet.robotics.rcx)
 
  Re: Maximum sample rate (turn rate) for rotation sensor
 
When using the standard firmware, sensors are sampled every 3 ms. The rotation sensor uses a quadrature encoder with a 1:4 gearing between the axle and the encoder, so there are 16 "ticks" per revolution of the axle. The decoding routine in the (...) (25 years ago, 21-Jul-01, to lugnet.robotics.rcx)
 
  Re: Maximum sample rate (turn rate) for rotation sensor
 
The hardware can actually do (in my testing) up to ~3000 rpm with good accuracy. The problem is with the standard software, which cannot do more than some low number (which may or may not be 500, I don't recall) because of how it samples the HW. (...) (25 years ago, 20-Jul-01, to lugnet.robotics.rcx)
 
  sample code for the remote patch (pc side)
 
Hi, is anybody using the remote patch ? I d be glad if anybody could post or send me some sample code for the pc-side where remote messages are send to the RCX. Thanx, Olaf Christ (25 years ago, 20-Jul-01, to lugnet.robotics.rcx.legos)
 
  rotation sensor question
 
I installed leJOS, got it up and running, then read on the sourceforge site a support question about the rotation sensor, so I decided to test it out. I wrote a first cut at it and it didn't work, just like the support question suggested: import (...) (25 years ago, 20-Jul-01, to lugnet.robotics.rcx.java)
 
  Maximum sample rate (turn rate) for rotation sensor
 
Does anyone know the correct maximum sampling rate for the Lego rotation sensor? This morning I noticed that Dave Baum gives a value of 1250 RPM in his "Definitive Guide" (page 29), but looking at (URL) see a value of 500 RPM. Which is correct? (...) (25 years ago, 20-Jul-01, to lugnet.robotics.rcx)