  Any idea how to get to run "Vision Command" under W2K?
 
Hello, everybody! Does someone have an idea, how to get the Mindstorm Vision Command to run under Win2000? Can you fool the software somehow (e.g. with VirtualPC)? Or are there W2K-driver-betas somewhere? On "NT Compatible" they say Lego Mindstorms (...) (26 years ago, 24-Jan-01, to lugnet.robotics.vc)
 
  Visual NQC 2001 Beta 2
 
To all testers, Runtime error 380 stands for invalid property. This can happen when you try to compile a program in the editor. I had the error ones during development but it didn't come up anymore. Next week I'm starting bugfixing again and see if (...) (26 years ago, 26-Jan-01, to lugnet.robotics.rcx.nqc)
 
  fiber optics conduit to light sensors
 
You can make a sturdy fiber optic cable conduit from Lego tubes and connectors. It can completely enclose at least two Lego fiber optic cables joined end-to-end from a light source to a light sensor. The conduit can shield a light sensor from (...) (26 years ago, 26-Jan-01, to lugnet.robotics.scout, lugnet.robotics.microscout, lugnet.robotics.vll)
 
  Re: How many motors can accept a RCX ?
 
The outputs on the RCX can sink about 500mA of current, and each motor draws up to 200mA when stalled. You can put two on the output and stall them before the thermal shutoff kicks in. I was under the impression (never tried it, mind you) that the (...) (26 years ago, 26-Jan-01, to lugnet.robotics)
 
  dodgy motor
 
The motor I got with my 8479 is very stiff - it can only be turned by hand with difficulty. It drives with power but more slowly than any others I have. It's not essential that I replace it as I have enough (from znaps etc). What should I do - put (...) (26 years ago, 26-Jan-01, to lugnet.robotics.codepilot)
 
  Re: Rotational Sensor & Gearing Down
 
(...) I find it really frustrating that this has to be "discovered" over and over. I believe my fix for LegOS (a year ago?) fixes this problem. The sensor itself is very good. It only ever returns the discrete voltages (which vary by cable length (...) (26 years ago, 26-Jan-01, to lugnet.robotics)
 
  Re: Rotational Sensor & Gearing Down
 
"Steve Baker" <lego-robotics@crynwr.com> wrote in message news:3A6EFF8A.416F3D...ail.net... (...) Nice post, but you only ran the sensors counting up for x number of seconds. Try *reversing*. Then watch what happens... (IE, bring a sensor back home. (...) (26 years ago, 26-Jan-01, to lugnet.robotics)
 
  How many motors can accept a RCX ?
 
Hi, everybody <DISCLAIMER> Excuse me first for my newbieness here on Lugnet. and also for my frenchieness, but it's not my fault ! </DISCLAIMER> I have a question I'd like to submit: Because of extreme needs of power/ acceleration (it was about (...) (26 years ago, 26-Jan-01, to lugnet.robotics.rcx)
 
  Re: Rotational Sensor & Gearing Down
 
Thanks to all for the good information that has been related here. Most of my applications were low rpm which seems to be a definite fault area. I like to use them for absolute programming of positions. I now see the problem in using them in these (...) (26 years ago, 25-Jan-01, to lugnet.robotics)
 
  Re: Rotational Sensor & Gearing Down
 
(...) Just don't go past it's Max or Min areas or you'll have a problem. This is probably a good place for the white slip gear... Dean -- Coin-Op's For Sale!: (URL) Lego Workshop: (URL) Lego Club: (URL) (26 years ago, 25-Jan-01, to lugnet.robotics)
 
  Re: Rotational Sensor & Gearing Down
 
(...) I just read the very interesting posting regarding testing the rotation sensor to evaluate the "missing counts" phenomenon. The above snippit would indicate that the rotation sensor is handled differently from other sensors. It isn't! It is (...) (26 years ago, 25-Jan-01, to lugnet.robotics)
 
  Re: CM-RCX comm
 
(...) Ok, one of many possible examples (we're talking about Lego, where your imagination is your limit... err... well, almost ;) I could use an input port of a RCX as a 4th motor controller, using VLL through the LED of a LightSensor connected to (...) (26 years ago, 25-Jan-01, to lugnet.robotics)
 
  LEGO Lab class
 
I don't frequent robotics, but I figured I'd post about the class I'm taking. So far, we haven't done any control, just building mechanical stuff. Here are the pictures: (URL) course web site: (URL) Lambrecht bram@cwru.edu (URL) (26 years ago, 25-Jan-01, to lugnet.robotics, lugnet.robotics.edu)
 
  Re: Rotational Sensor & Gearing Down
 
(...) But I don't think you did what we reported IS the problem... Did you run the motor FORWARD, then REVERSE so we can see the missing positions? That's where the errors come in. Dean -- Coin-Op's For Sale!: (URL) Lego Workshop: (URL) Lego Club: (...) (26 years ago, 25-Jan-01, to lugnet.robotics)
 
  Re: Rotational Sensor & Gearing Down
 
(...) I think the PIC series of microcontrollers have some sample code for reading quadrature-type rotational sensors (a la mousewheels). Perhaps one could design a PIC-based intermediate module that was dedicated to reading rotational sensors (...) (26 years ago, 24-Jan-01, to lugnet.robotics)
 
  Re: Rotational Sensor & Gearing Down
 
(...) OK - time for the rigerous scientific approach here (well - OK - the half-assed semi-scientific Steve Baker method :-)... I'm typing this email as I run the tests...so right now, I don't know the answers... Test 1: Connect two rotation sensors (...) (26 years ago, 24-Jan-01, to lugnet.robotics)
 
  RE: Confusion regarding the POWER_OFF command.
 
(...) I was too. It's a bit goofy, so I'll try to explain as I go... (...) That's fine - the only thning you need to do (I think - I'm away from my RCX) is to put POWER_INIT just before POWER_OFF. The POWER_INIT word initializes the interrupt (...) (26 years ago, 25-Jan-01, to lugnet.robotics.rcx.pbforth)
 
  Re: Visual NQC 2001
 
I have downloaded and installed Beta 2. I am having a problem that I had with beta 1. When I "Compile" I get a "Runtime Error '380' Invalid Property Value". Am I alone in this problem? If so, what does it mean? Is something missing from my Win98? -- (...) (26 years ago, 25-Jan-01, to lugnet.robotics.rcx.nqc)
 
  Re: sleep efficientcy
 
(...) value (...) There are two issues: 1 do you want to do anything while waiting, 2 how quick do you want to respond to the event. In both cases using an event is better. You can do something else until the event happens (synchronization issuses (...) (26 years ago, 25-Jan-01, to lugnet.robotics.rcx.legos)
 
  Visual NQC 2001
 
I've fixed a lot of problems thanks to your testing and reporting. Beta relase 2 is now available on (URL) (26 years ago, 25-Jan-01, to lugnet.robotics.rcx.nqc)