 | | >>> RIS vs. RDS <<<
|
|
Hi, what's the diference between RIS and RDS ? Thanx. Norbert (26 years ago, 31-Oct-00, to lugnet.robotics)
|
| |
 | | Increase RCX outputs.
|
|
I expanded the RCX outputs from 3 to 12 (6 sets of 2)using 2 rotary switches and one feedback POT (50k ohm). The 3rd RCX output is used to to energize a motor that rotates both rotary switches and the pot simultaneously( they are mechanically liked (...) (26 years ago, 31-Oct-00, to lugnet.robotics)
|
| |
 | | A reset key for pbforth
|
|
Hi all, as I am one of those people who cannot remember the order of the arguments to DUMP, I wrote a simple interrupt handler to use RUN as a reset key (like ctrl-alt-del on a PC). Comments are welcome here, or by email. Ernst Include the following (...) (26 years ago, 30-Oct-00, to lugnet.robotics.rcx.pbforth)
|
| |
 | | Re: IR Proximity Detector Kit
|
|
Yes, check out my web site nfn.no-ip.com/spazbot. It works great! I wrote the code to pull it off, it's not too hard. The code should be posted at lynxmotion, if it's not I can send you an example. (...) (26 years ago, 30-Oct-00, to lugnet.robotics.handyboard)
|
| |
 | | Re: RCX2
|
|
Bill, If you go to (URL) then follow the 'Tips and Tricks' link, the RCX2 beta SDK is under the 'Master Coders' section. A quick quote from the site: <quote> RCX 2.0 BETA SDK Since we made a few small changes and additions to the firmware after we (...) (26 years ago, 30-Oct-00, to lugnet.robotics)
|
| |
 | | Re: Why 2 robotics newsgroups?
|
|
[followups to lugnet.admin.nntp] (...) Well, actually, there's only one lugnet.robotics newsgroup. It does has subgroups, however, so perhaps that is what you were seeing? At any rate, the first URL you gave above (well, partial URL -- it's missing (...) (26 years ago, 30-Oct-00, to lugnet.robotics, lugnet.admin.nntp)
|
| |
 | | Re: IR Proximity Detector Kit
|
|
(...) to (...) I've used similar 555/IR detector ones. They work fine, but you have to do a lot of filtering to "get the noise out". Because of that I wrote a PIC 12C508 program that handles the noise filtering and signal processing and just sets a (...) (26 years ago, 30-Oct-00, to lugnet.robotics.handyboard)
|
| |
 | | Re: Rant
|
|
One point that hasn't been mentioned in all the foregoing discussions about Lego's direction with the new Technic sets is what I think must be of vital concern to them and that is "critical pieces". Especially these days, now it's so easy to (...) (26 years ago, 30-Oct-00, to lugnet.robotics)
|
| |
 | | RCX2
|
|
Hi, I'm interested in RCX2 firmware. Is it something that can be downloaded? What capabilities does it have? TIA, Bill Weiss Senior Software Developer ASSET InterTech, Inc. bweiss@asset-intertech.com (26 years ago, 30-Oct-00, to lugnet.robotics)
|
| |
 | | Re: text location for apps and q?
|
|
Hello, (...) No they don't have a separate address space. I think the limit is 19456 bytes for the kernel, and this is caused by a limitation of the ROM, which is used to download the firmware (kernel). It loads it to the address range 8000-cc00. (...) (26 years ago, 30-Oct-00, to lugnet.robotics.rcx.legos)
|