To LUGNET HomepageTo LUGNET News HomepageTo LUGNET Guide Homepage
 Help on Searching
 
Post new message to lugnet.roboticsOpen lugnet.robotics in your NNTP NewsreaderTo LUGNET News Traffic PageSign In (Members)
 Robotics / *22499 (-10)
  Re: 6.8 nF Capacitor
 
The 6.6nF was the capacitance measured for the two 6.8nF capacitors that I have managed to get (rated as 10% tolerance). The problem is that the parts listed for the HB are 2% tolerance 6.8nF capacitors which gives a lowest value of 6.6664nF which (...) (26 years ago, 6-Jul-00, to lugnet.robotics.handyboard)
 
  Re: 6.8 nF Capacitor
 
(...) Yes. Capacitors have typically very loose tolerances anyhow; usually 20% unless you buy specifically selected samples in a tighter tolerance. The 6.8 is a standard value while the 6.6 you have is likely a specially selected non-standard value. (...) (26 years ago, 6-Jul-00, to lugnet.robotics.handyboard)
 
  6.8 nF Capacitor
 
Can any body tell me if a 6.6nF capacitor will do to replace the 6.8nF in the IR Transmission circuit (Fred?) ?. Thanks in advance. John Hatton (26 years ago, 6-Jul-00, to lugnet.robotics.handyboard)
 
  HB to Comms board cable
 
Is there a 'best' length for the telephone cable between the HB and the Comms board. I am about to start construction and I was wondering if there was a maximum length for the cable and if a particular length was recommended. Thanks for your help. (...) (26 years ago, 6-Jul-00, to lugnet.robotics.handyboard)
 
  Re: Connect HP 48GX
 
Gruezi/ Hi, (...) Instead of using the serial port, how about using the HP4**x IR port? I recall there being HP4**x programs that emulate IR remote controls which should be easy to modify (?) for general-purpose communications. Marco A. Assfalk de (...) (26 years ago, 6-Jul-00, to lugnet.robotics.handyboard)
 
  Caution when using DCP container constructs
 
In Robolab 2.0 the eight DCP container constructs store the raw value of the sensor. This means the value stored is not in rotations, volts, dB, etc. but in a raw measurement of these values. This raw value cannot be easily used with other Robolab (...) (26 years ago, 5-Jul-00, to lugnet.robotics.rcx.robolab)
 
  Minor bug in DCP sound sensor support
 
Robolab 2.0 and 2.01 programmer extras has a bug in the DCP sound sensor construct "Wait for increasing sound". This construct sets the sensor type to touch when it should set the sensor type to light. The other sound sensor constructs "Wait for (...) (26 years ago, 5-Jul-00, to lugnet.robotics.rcx.robolab)
 
  Handyboard startup problems
 
Hi all, I'm having some problems with me previously functioning handyboard. I'm using a standard board which has worked fine for nearly a year. Recently it didn't get any use for awhile and the batteries ran down. After charging them for 18+ hours I (...) (26 years ago, 5-Jul-00, to lugnet.robotics.handyboard)
 
  Re: legOS battery life code
 
Sorry! I forgot to post the code. Here it is: #include <dsensor.h> #include <dlcd.h> #include <conio.h> int get_battery_mv() { long b; int mv; b = BATTERY; b = ds_scale(b) * 0xABD4L; mv = b / 0x618L; return mv; } int main(int ac, char **av) { int b; (...) (26 years ago, 5-Jul-00, to lugnet.robotics.rcx.legos)
 
  legOS battery life code
 
Hello, I recently received some code in the mail that when compiled and uploaded to the RCX is supposed to give you the battery life. But when I go to compile it, legOS/util/makelx gives me the following error message: single byte different at (...) (26 years ago, 5-Jul-00, to lugnet.robotics.rcx.legos)