 | | Re: GA in RCX
|
|
(...) I like the multiple robot idea. If each robot used a simulated annealing algorithm instead of a GA this would require less computation since it would be working on one chromosome instead of a population. Each robot could advertise its fitness (...) (26 years ago, 25-May-00, to lugnet.robotics.rcx.legos)
|
| |
 | | Re: Digital outputs.
|
|
Todd, The outputs can control a transistor, that is powered by a separate higher current o/p. (Poor text diagram following) Vsupply _ | / Dig Out ---...---| <- Tansistor \ | |__ Vout (...) Charles Hacker Lecturer in Electronics, Computing and (...) (26 years ago, 25-May-00, to lugnet.robotics.handyboard)
|
| |
 | | Re: batteries? RCX/CYBERMASTER
|
|
(...) The RCX will work off about 7volts as long as you don't use too many motors. (...) If you have RCX 1.0 with power adapter port you can use any 9~12 volt adapter. The lego train ones work great. AC or DC. For the RCX 1.5, scout and CYBERMASTER (...) (26 years ago, 25-May-00, to lugnet.robotics)
|
| |
 | | Digital outputs.
|
|
How would I go about making the digital outputs capable of controlling a higher current than the 5 ma that is standard? Can a switching transistor be controlled by them? Or do I need some sort of IC to do the job? Particularly I would like to be (...) (26 years ago, 25-May-00, to lugnet.robotics.handyboard)
|
| |
 | | Re: NQC and rcx2
|
|
(...) No doc yet. It probably won't happen for a while. There are still features that need to be implemented! Dave (26 years ago, 25-May-00, to lugnet.robotics.rcx.nqc)
|
| |
 | | Re: NQC and rcx2
|
|
(...) Documentation is always the last thing to get done.... Until I get it completed, your best bet is to read the lego documentation - especially the opcodes monel,monex,monal, and monax. The monitor/catch works like this: monitor(events) { // (...) (26 years ago, 25-May-00, to lugnet.robotics.rcx.nqc)
|
| |
 | | Re: batteries? RCX/CYBERMASTER
|
|
in article Fv2qqJ.A3s@lugnet.com, Guido Heunen at heunen@crys.chem.uva.nl wrote on 5/24/00 10:18 AM: (...) I don't have a CyberMaster, but rechargeables work fine in my Scout and my RCX. My favorite battery is lithium hydride (LiH). They are quite (...) (26 years ago, 24-May-00, to lugnet.robotics)
|
| |
 | | Re: batteries? RCX/CYBERMASTER
|
|
Guido Heunen schreef: (...) I am using Panasonic rechargables, available at Conrad Electronics in the Netherlands, which work excellent for the RCX, Scout and Cybermaster. RCX reports 8.4 volt power when fully charged. They're only a fraction more (...) (26 years ago, 24-May-00, to lugnet.robotics)
|
| |
 | | LCD_NUMBER, made it work.
|
|
(...) I got it finally after re-reading the doc a few times. My arguements were in the wrong order. (26 years ago, 24-May-00, to lugnet.robotics.rcx.pbforth)
|
| |
 | | LCD_NUMBER, Can't make it work.
|
|
The following has no effect: HEX 3002 301F 22 LCD_NUMBER LCD_REFRESH The following do as expected: LCD_4TH LCD_REFRESH LCD_CLEAR LCD_REFRESH Am I missing something? I've tried a few other things with LCD_NUMBER. Once I got 9999 on the display (that (...) (26 years ago, 24-May-00, to lugnet.robotics.rcx.pbforth)
|