In lugnet.dacta, Yves Levesque wrote:
Hi,

I just added a demo file in the folder http://www.box.net/shared/xc44rksi2h.
It is called LegoMultiCLISetup.zip and contains the installable test application
for multiple (Max 3) CLIs.

I would appreciate if someone could try it with 2 or 3 CLIs at the same time and
give me some feedback.  I have only one CLI and cannot test this Multiple CLI
control feature.

Once installed, start the application, Select Com ports for the CLIs that are
connected to your PC.  Don't forget to put a "Checkmark" to the port you want to
use.

Press Start CLIs.  Pressing a Switch on port1 of any CLI will start motors on
port 1 of other CLIs.  Release the switch to stop motor(s).

Ex., If you use 3 CLIs, pressing a Switch on Port 1 of of CLI#1 will start
Motors on port 1 of CLI#2 and CLI#3.  A switch on port 1 of CLI#2 will
start/stop motors on CLI#1 & 3.

Thank you for your feedback.

Yves

I did some quick testing on the LegoMultiCLI program that you posted. I was able
to connect two CLIs to my computer as follows:

CLI 1: connected to COM1 serial port
CLI 2: connected to COM6 (using USB to Serial adaptor)

I ran the program and selected the appropriate COM ports and then hit the Start
button.  I had a touch sensor connected to port 1 on CLI 1.
When I pressed the touch sensor, the output 1 did start properly on CLI 2.
When I released the touch sensor though, the output remained on.  The input
light on CLI 1 would toggle on and off with each press of the sensor, but the
output on CLI 2 only reponded to the first press.

I moved the touch sensor to CLI 2 and it had the same effect where the output on
CLI 1 only responded to the first press.

Any ideas?

I will try to get VB installed in the next couple days so that I can view the
source code files to help with some testing.

Brian



Message has 1 Reply:
  Re: ControlLab 70909 Interface (9751?) VB.NET Class (DLL)
 
(...) Thank you Brian. I made a mistake and corrected it I think. So you can download the updated file (same name) from the same url mentionned before. But according to what your saying, it sounds good. Thank you very much for your interest. Yves (15 years ago, 11-Jan-10, to lugnet.dacta)

Message is in Reply To:
  Re: ControlLab 70909 Interface (9751?) VB.NET Class (DLL)
 
Hi, I just added a demo file in the folder (URL) is called LegoMultiCLISetup.zip and contains the installable test application for multiple (Max 3) CLIs. I would appreciate if someone could try it with 2 or 3 CLIs at the same time and give me some (...) (15 years ago, 10-Jan-10, to lugnet.dacta)

17 Messages in This Thread:



Entire Thread on One Page:
Nested:  All | Brief | Compact | Dots
Linear:  All | Brief | Compact

This Message and its Replies on One Page:
Nested:  All | Brief | Compact | Dots
Linear:  All | Brief | Compact
    

Custom Search

©2005 LUGNET. All rights reserved. - hosted by steinbruch.info GbR