| | Re: Beta Tester(s) wanted NQCSpeechCompiler
|
|
(...) (URL) (22 years ago, 25-Oct-02, to lugnet.robotics.rcx.nqc)
|
|
| | Re: Beta Tester(s) wanted NQCSpeechCompiler
|
|
"Stef Mientki" <s.mientki@ids.kun.nl> wrote in message news:H4IC2q.8HB@lugnet.com... (...) Dasher? No, do you have a URL? Dean (...) and (...) as (...) the (...) felt (...) spirit (...) correspondence. (...) (22 years ago, 25-Oct-02, to lugnet.robotics.rcx.nqc)
|
|
| | Re: Beta Tester(s) wanted NQCSpeechCompiler
|
|
hi Dean, ever heard of "Dasher", could be an alternative too ? Stef (...) (22 years ago, 24-Oct-02, to lugnet.robotics.rcx.nqc)
|
|
| | Controlling larger motors from RCX ??
|
|
We need to control larger motors with a separate 12V power supply, from the RCX outputs. We would like to 'mirror' the RCX bipolar, pulse-width-modulated outputs to a separate circuit with a larger H-bridge that is (probably) electrically isolated (...) (22 years ago, 7-Oct-02, to lugnet.robotics, lugnet.robotics.rcx, lugnet.robotics.rcx.nqc)
|
|
| | MacNQC Beta Release 3.0a6
|
|
Hi All, I've uploaded MacNQC 3.0a6. New features are: * Tooltips for the Toolbar. Bugs fixed: * Disabled the Fast Firmware checkbox when the USB tower is selected as the output device. * Fixed a crash if while compiling a one line error message is (...) (22 years ago, 3-Oct-02, to lugnet.robotics.rcx.nqc)
|
|
| | New version of Robot Controller
|
|
Version 1.6b2 of Robot Controller is available, either from Version Tracker, or from my new web page: (URL) it out, and tell me what you think! In case you don't know, Robot Controller is a MacOS X application for controlling and testing RCX robots (...) (22 years ago, 30-Sep-02, to lugnet.robotics.rcx.nqc)
|
|
| | How to find maximum available memory for datalog, power consumption and sensor wire length?
|
|
Hi there, I'm preparing to write a log program to store temperature values in the datalog. After some experimenting and familiarizing with the datalog associated functions I've found the following: Using CreateDatalog(x) with x being a constant and (...) (22 years ago, 30-Sep-02, to lugnet.robotics.rcx.nqc)
|
|
| | Re: VPBRICK
|
|
(...) This should work: SetEvent(My_Event, Message(), EVENT_TYPE_MESSAGE); Dave (22 years ago, 20-Sep-02, to lugnet.robotics.rcx.nqc)
|
|
| | VPBRICK
|
|
Hello! I have some questions: - (in the RCX side) How i can configure a message Event in NQC, I don't know the second parameter? SetEvent(My_Event,??..._Message); - (in the PC side to get the messages from the RCX), anybody have a sample code to use (...) (22 years ago, 18-Sep-02, to lugnet.robotics.rcx.nqc)
|
|
| | Re: RCX simulator ?
|
|
(...) Yes, to give you even a better idea, I made a page with some of the ideas (and pictures ofcourse), see (URL) Mientki (22 years ago, 16-Sep-02, to lugnet.robotics, lugnet.robotics.rcx, lugnet.robotics.rcx.nqc)
|