To LUGNET HomepageTo LUGNET News HomepageTo LUGNET Guide Homepage
 Help on Searching
 
Post new message to lugnet.robotics.rcx.nqcOpen lugnet.robotics.rcx.nqc in your NNTP NewsreaderTo LUGNET News Traffic PageSign In (Members)
 Robotics / RCX / NQC / *962 (-10)
  Re: Visual NQC 2001
 
I have another problem with Visual NQC 2001. If I dump my firmware, the program will not recognize the brick. "Runtime Error '68' Unable to communicate with PBrick from method 22" Of course, I could not download the firmware. I hope we could get (...) (24 years ago, 4-Feb-01, to lugnet.robotics.rcx.nqc)
 
  Re: Visual NQC 2001
 
(...) I found that if I use the DOS names instead of Windows name, it works. Example C:\PROGRA~1\RSSOFT~1...~1\NQC.exe instead of C:\Program Files\RSsoftware\Visual NQC 2001\NQC.exe Marc Klein (24 years ago, 4-Feb-01, to lugnet.robotics.rcx.nqc)
 
  Re: MST...
 
Sorry, there still seem to be bugs in the prog. I'll call when I've fixed them... (24 years ago, 3-Feb-01, to lugnet.robotics.rcx.nqc)
 
  MST...
 
Hi, thanks to the help especially of Andreas Koeller, I was able to spot the errors in my program and even make it faster. The new version ist available for download at (URL) (rename to .nqc after downloading). Remember, it takes a graph of the form (...) (24 years ago, 3-Feb-01, to lugnet.robotics.rcx.nqc)
 
  advice for game of tag?
 
Hi, I've got 2 bots that I want to play tag with each other. The challenge is that I want them to see each other at a distance. I'm working on some code to combine the IR ports with the light sensors (which can detect IR) as follows: 1) each sends (...) (24 years ago, 3-Feb-01, to lugnet.robotics.rcx.nqc)
 
  nqc download firmware linux
 
Hi; I'm using RCX1.0 on linux (kernel 2.2.16; SuSE 7.0), nqc-version 2.0.2 and I have troubles with downloading the firmware under linux. I always have to change to Win98 and then the download works fine. On Linux I say at the prompt: nqc -firmware (...) (24 years ago, 2-Feb-01, to lugnet.robotics.rcx.nqc)
 
  Re: Visual NQC 2001
 
Tim Webber pointed out to me that I must set the path to nqc.exe in the preferences. All is well now, thanks to Tim. -- Bob Fay California, USA rfay@we.mediaone.net (URL) (24 years ago, 2-Feb-01, to lugnet.robotics.rcx.nqc)
 
  Re: Anyone using Mac beige G3
 
(...) The serial ports weren't changed in a major way (still RS-422, etc), but there could have been subtle changes to the driver/receiver that would cause problems when hooked to marginal RS-232 devices (such as the IR tower). Fred Martin reported (...) (24 years ago, 2-Feb-01, to lugnet.robotics.rcx.nqc)
 
  Re: Visual NQC 2001
 
<Runtime error 380 fix If you get Runtime error 380 during compile start you need to change the subdirectory where NQC.exe is stored. Use a directory without a space in the name. Example C:\NQC\nqc.exe This will work.> That did not work. I am still (...) (24 years ago, 1-Feb-01, to lugnet.robotics.rcx.nqc)
 
  Re: Anyone using Mac beige G3
 
(...) One thing to keep in mind about Mac serial ports is that they are not RS-232, rather they are RS-422. IIRC, RS-232 is a singled-ended voltage standard (ref to ground only), where RS-422 is a differential standard. The 'common' method of using (...) (24 years ago, 1-Feb-01, to lugnet.robotics.rcx.nqc)


Next Page:  5 more | 10 more | 20 more

Redisplay Messages:  All | Compact

©2005 LUGNET. All rights reserved. - hosted by steinbruch.info GbR