To LUGNET HomepageTo LUGNET News HomepageTo LUGNET Guide Homepage
 Help on Searching
 
Post new message to lugnet.robotics.rcx.legosOpen lugnet.robotics.rcx.legos in your NNTP NewsreaderTo LUGNET News Traffic PageSign In (Members)
 Robotics / RCX / legOS / *209 (-10)
  Re: light values?
 
Ah... that makes sense- I didn't realize that power was completely cut. Should have (I'm not *that* incompetent in reading electronics diagrams). Oh well. Thanks for the feedback, John... Luis (...) ###...### God was my co-pilot, but we crashed in (...) (25 years ago, 28-May-99, to lugnet.robotics.rcx.legos)
 
  Re: light values?
 
(...) The light sensor is an active sensor, which means that it requires power to operate. When you call ds_passive, you are no longer supplying power to the sensor between readings. Some people have reported being able to use the light sensor for (...) (25 years ago, 28-May-99, to lugnet.robotics.rcx.legos)
 
  Re: light values?
 
Some months ago, I posted this question, but got no response. I've finally played with it some more this morning and have some observations: 1) After setting ds_active, my light sensor returns values of 0-100, as I should. 2) After calling (...) (25 years ago, 28-May-99, to lugnet.robotics.rcx.legos)
 
  Re: Lego Network Protocol questions
 
In lugnet.robotics.rcx.legos, Kekoa Proudfoot writes: [ ... ] (...) To this end, i've started work on a Discrete Event Simulator. The idea is to use this to see the effects of some of the things you mention above. Note that this is not an (...) (25 years ago, 21-May-99, to lugnet.robotics.rcx.legos, lugnet.robotics)
 
  Download at www.multimania.com
 
Hi, I'm not sure exactly why this is, but for some reason I can't get a binary download to work from .. (URL) .. Whenever I try and download any of the files from this server ( using both a PPP line at home, and the connection at Uni.) I get (...) (25 years ago, 16-May-99, to lugnet.robotics.rcx.legos)
 
  Re: firmdl question
 
(...) I believe the units are tens of firmware bytes downloaded already. Oh, to point out the obvious, this is a ROM thing, not a firmdl thing. -Kekoa (25 years ago, 13-May-99, to lugnet.robotics.rcx.legos)
 
  Re: Rom sensor read routine
 
(...) The current LegOS model really hammers the sensors, almost to the point of oversampling them. It only takes a short while (less than 0.1 ms, I think) to sample all four sensors; I think LegOS samples the next sensor immediately after finishing (...) (25 years ago, 13-May-99, to lugnet.robotics.rcx.legos)
 
  firmdl question
 
When using firmdl to download a program to the RCX, what exactly do the numbers on the LCD indicate? Are there units I should be attaching to them, or are they just there to indicate progress without specific units? Just curious- Luis ###...### God (...) (25 years ago, 13-May-99, to lugnet.robotics.rcx.legos)
 
  Re: Rom sensor read routine
 
Hi Kekoa, (...) I am fixing this right now. (...) The current legOS sensor read cycle is this (i=illuminate, c=A/D conversion) S1: iii iii iii ccc S2: ccc iii iii iii S3: iii ccc iii iii S4: iii iii ccc iii If you find your sensor 2 readings to be (...) (25 years ago, 2-May-99, to lugnet.robotics.rcx.legos)
 
  Re: Lego Network Protocol questions
 
(...) I believe transmission and reception are independent, i.e. the emitter circuit is decoupled from the receiver circuit. The hardware on the H8 is full duplex. Once you finish sending a byte, I think you get two interrupts: one saying a byte has (...) (25 years ago, 5-May-99, to lugnet.robotics.rcx.legos, lugnet.robotics)


Next Page:  5 more | 10 more | 20 more

Redisplay Messages:  All | Compact

©2005 LUGNET. All rights reserved. - hosted by steinbruch.info GbR