| | Battery voltage levels
|
|
I have two RCXs: a version 1.0 with external power connector, and a version 2.0 without. They consistently report different voltages on the same batteries: the 2.0 puts all batteries about 0.3v higher. I want to know how much variation there is (...) (22 years ago, 7-Oct-02, to lugnet.robotics.rcx)
|
|
| | Re: Battery voltage levels
|
|
"Barney Hilken" <b.hilken@ntlworld.com> wrote in message news:H3LyHy.76H@lugnet.com... (...) version 2.0 (...) batteries: the (...) variation (...) on (...) email (...) Robot (...) don't (...) There is going to be a difference between the 1.0's (...) (22 years ago, 7-Oct-02, to lugnet.robotics.rcx)
|
|
| | Re: Battery voltage levels
|
|
(...) Thanks, this explains the difference. However, I'm still interested in the voltage levels people get. Does anyone use NiCads? Or rechargeable alkalines? Or something else I've not thought of? Barney. (22 years ago, 7-Oct-02, to lugnet.robotics.rcx)
|
|
| | Re: Battery voltage levels
|
|
"Barney Hilken" <b.hilken@ntlworld.com> wrote in message news:H3MuHC.2CM@lugnet.com... (...) volts (...) The (...) circuits. [snip] (...) alkalines? (...) I use Nickel Hydride rechargeables in an RCX1.0, at least that's what it says on the top - (...) (22 years ago, 8-Oct-02, to lugnet.robotics.rcx)
|