Hi,

yeah... me I just went through such trouble using Java. The RTS should
be 'false'. Then by experimenting I found switching the DTR before and after
sending to have some positive effect.

I trust you adhere to
+ starting a session with 'Alive' followed by 'Unlock Firmware'
+ the packaging of the byte codes with the
  [header bytes] [byte] [~byte] ... [sum of byte] [~sum of byte]
+ the different header bytes (and reply header bytes) for rcx and cm
  CM header to robot  0xfe 0x00 0x00 0xff
          from robot  0xff
  RCX       to robot  0x55 0xff 0x00
          from robot  0x55 0xff 0x00

the difficult part is the reading. I had lost of troubles figuring out
if there was something -real/meaningfull- to READ on the port.
A couple of evenings of experimenting, and improving the reading logic
were necessary.

Cheers,
Theo.

In lugnet.robotics, Oliver Kutsche writes:
Hi,

I've written a small Visual Basic program so I can use Cybermaster under
Windows 3.1x. (So I cannot use spirit.ocx.)

Sending commands works (motor on/off, sound, etc.). But I don't get any
echo. I cannot get any sensor data, and I can't see if my commands are
correctly received by the Spirit unit.


I use mscomm.vbx for communicating with the RC tower:

' 2400 baud, odd parity, 8 data bits, 1 stop bit:
Comm1.Settings = "2400,o,8,1"

' setting InputLen to 1 or 15 doesn't seem to change anything:
Comm1.InputLen = 0

' opening port:
Comm1.PortOpen = True

' setting flags:
Comm1.DTREnable = True ' set dtr
Comm1.RTSEnable = True ' set rts
Comm1.CDHolding = False ' set cd
Comm1.CTSHolding = False ' set cts
Comm1.DSRHolding = False ' set dsr

The Spirit unit seems to send something (LED flashes) but the RC tower
doesn't receive anything (no LED activity unless it's sending).

When I connect to a modem, receiving data works (e.g. 'OK.' after 'AT').
BTW, of course the Cybermaster CD works, too (e.g. Arena reacts to punches
on sensors and Garage can read battery power)


BTW, another problem: When I send to commands in a row the second is not
understood by the Spirit unit until I have a pause of about 100 ms between
two commands.

Does anybody have a suggestion?

TIA,
   Oliver



Message has 1 Reply:
  It works! [was: Cybermaster: Cannot receive though sending works (w/o sprit.ocx)]
 
"Theo van Eijndhoven" <theo@sympro.nl> schrieb im Newsbeitrag news:G7o2AM.AFL@lugnet.com... (...) Yippie! That did it! I set RTS to false and now it works! Thank you! -Oli -- "If it ain't broken don't fix it!!" (24 years ago, 27-Jan-01, to lugnet.robotics, lugnet.robotics.cybermaster, lugnet.robotics.rcx)

Message is in Reply To:
  Cybermaster: Cannot receive though sending works (w/o sprit.ocx)
 
Hi, I've written a small Visual Basic program so I can use Cybermaster under Windows 3.1x. (So I cannot use spirit.ocx.) Sending commands works (motor on/off, sound, etc.). But I don't get any echo. I cannot get any sensor data, and I can't see if (...) (24 years ago, 22-Jan-01, to lugnet.robotics, lugnet.robotics.cybermaster, lugnet.robotics.rcx)