| | Re: Piggybacking sensors, but in a different way
|
|
(...) While you may be able to connect a touch sensor (passive) to two RCXs, I doubt that would work with a light sensor (any active sensor). Mainly, because one of them must be set to power the sensor. Normally, when the sensor is read by an RCX, (...) (20 years ago, 26-Oct-04, to lugnet.robotics.rcx)
|
|
| | Piggybacking sensors, but in a different way
|
|
Is it possible to piggyback 1 sensor onto two rcx's? For instance, have one light sensor connected to port 1 of two different rcx's at the same time. The purpose would be for one rcx to control chassis movement, and another to control manipulator (...) (20 years ago, 26-Oct-04, to lugnet.robotics.rcx)
|
|
| | Re: Rotation sensor limitation
|
|
(...) The simplest answer is to try it. Yes the limit that an RCX 16 bit integer can hold is 32767. From there things go to -32768 down to zero I think. (...) Kevin (20 years ago, 25-Oct-04, to lugnet.robotics.rcx.nqc)
|
|
| | Robolab/RCX program code size and limits.
|
|
Hi, I'm using Robolab 2.5.3 and RCS firmware revision 03.01 03.28. I have a couple of questions: - I want to demonstrate the difference in code size between a program written using subroutines versus a program written using subVi's. How do I (...) (20 years ago, 24-Oct-04, to lugnet.robotics.rcx.robolab)
|
|
| | Rotation sensor limitation
|
|
I use a rotation sensor for a brick sorting machine hence I need to know the limitation of the rotation sensor. What happens when the rotation sensor exceeds 9999 as shown on the LCD display? Apparently the rotation sensor can still keep track of (...) (20 years ago, 24-Oct-04, to lugnet.robotics.rcx.nqc)
|