| | RE: Ideas for NQC
|
| (...) I could not agree more with Kevin. Adding a feature, such as adding in more intricate math functions, or add in tcp/ip socket support, etc. is more fruitful than making the language syntax more like others just because someone is not used to (...) (21 years ago, 9-Mar-04, to lugnet.robotics.rcx.nqc)
| | | | Re: Ideas for NQC
|
| (...) I object to this proposed change. Lack of knowledge of a language's syntax does not justify changing the syntax. (...) [SNIP] Kevin (21 years ago, 9-Mar-04, to lugnet.robotics.rcx.nqc)
| | | | Re: Voltage>10V????
|
| Hi, (...) maybe your RCX is broken? What value do you get, >28000? Jürgen (21 years ago, 9-Mar-04, to lugnet.robotics.rcx.java)
| | | | Re: Change the the parity setting of the IR tower.
|
| Hi, (...) that depends on which tower you are talking about: - For the serial tower just do it. - For the USB tower it seems you can't, as there is no documented function to do that. Jürgen (21 years ago, 9-Mar-04, to lugnet.robotics.rcx)
| | | | Re: Ideas for NQC
|
| (...) Well, it won't be easy. It doesn't help that I've been working long hours at my day job either. But I'll do my best. (...) [...] (...) In C & C++ it is not optional to use a semi-colon at the end of a line. The same goes for Java, C#, and (...) (21 years ago, 9-Mar-04, to lugnet.robotics.rcx.nqc)
| | | | Re: USB tower/Linux/Firmdl not working nicely together
|
| (...) I have a working USB-tower in linux 2.4.21 using the cvs legousbdriver and nqc2.5r3. I use nqc for brickos installation 2.5.09 and dll included for lx uploads. I think I patched the brickos source with a usb patch from either (...) (21 years ago, 9-Mar-04, to lugnet.robotics.rcx.legos)
| | | | RE: Ideas for NQC
|
| (...) ...a bit like NQP (Not Quite Pascal) :D ? (...) That would have to be called NQB (Not Quite BASIC) ;) Ok, now, seriously, this could be usefull for lazzy typists like me, but remember that C is case sensitive, so, how could BricxCC decide (...) (21 years ago, 9-Mar-04, to lugnet.robotics.rcx.nqc)
| | | | Voltage>10V????
|
| Hi and thanks to all that answered my questions. I'm using the method 'getVoltageMilliVolt()' in my robot. But i don't understand the value that i get, more than 10000 mV, why? if 9600mV is the total voltage that batteries provide. Bye and thanks (...) (21 years ago, 9-Mar-04, to lugnet.robotics.rcx.java)
| | | | Change the the parity setting of the IR tower.
|
| Can I change the parity setting of ther IR tower so that I can use 8 data bit, no parity, 1 stopbit instead of 8 databit, odd parity, 1 stopbit. I want to access the IR tower with a serial port that has only the settings 8N1. (21 years ago, 9-Mar-04, to lugnet.robotics.rcx)
| | | | Ideas for NQC
|
| Hi John, Now that Dave Baum has given you the control under NQC, how will you manage to work both on NQC and on BricxCC??? I recomend the following changes: For NQC, something that you can add is optional use of semi-colon. It's a pain when I do a (...) (21 years ago, 8-Mar-04, to lugnet.robotics.rcx.nqc)
| |