To LUGNET HomepageTo LUGNET News HomepageTo LUGNET Guide Homepage
 Help on Searching
 
Post new message to lugnet.robotics.rcxOpen lugnet.robotics.rcx in your NNTP NewsreaderTo LUGNET News Traffic PageSign In (Members)
 Robotics / RCX / *8245 (-10)
  Re: Help w/install _or_ It all went so well
 
(...) You can do make fontdesign in the util directory to create fontdesign.exe I have managed to get brickos-0.2.6.10 working using gcc 3.3.1 on win98 under cygwin, though I had a few problems along the way. At this stage I have only tried a few of (...) (21 years ago, 9-Dec-03, to lugnet.robotics.rcx.legos, FTX)
 
  Strange RCX startup issues
 
Hello, using brickOS v0.2.6.10... When I declare an object of type Motor and assign it a port outside of main() the RCX does not run the program at all, I have to remove batteries and reload firmware to get it back to normal. Is this related to the (...) (21 years ago, 9-Dec-03, to lugnet.robotics.rcx.legos)
 
  Re: Remote Message Buttons
 
That doesn't seem to help, doing things that way actually made the Stop and Beep buttons function as Stop and Beep. I was hoping to have all the buttons "raw" messages available to remap their functionality. I think I know how to modify the kernel (...) (21 years ago, 9-Dec-03, to lugnet.robotics.rcx.legos)
 
  Logging sensor data
 
Hi there, I'm quite new to the Mindstorms and LegOS/BrickOS scene but have recently begun using the kits for robotics purposes in University. They have been a revelation to me and speed up prototyping projects to no end. My question though concerns (...) (21 years ago, 9-Dec-03, to lugnet.robotics.rcx.legos)
 
  Re: Remote Message Buttons
 
(...) I just use the standard IR message stuff from BrickOS. They are normal messages, so this works just fine. Here are some lines of code: (I think it's in lnp.h) #include <sys/lnp.h> ... clear_msg(); ... if (msg_received != 0) my_message_value = (...) (21 years ago, 8-Dec-03, to lugnet.robotics.rcx.legos)
 
  Remote Message Buttons
 
Hello, Anyone had problems getting the message 1,2,3 buttons working with brickOS? All other remote buttons are working. I am using v0.2.6.10. I looked through the kernel and includes, it looks like in lr_process(), the lr_keys gets checked vs. (...) (21 years ago, 8-Dec-03, to lugnet.robotics.rcx.legos)
 
  Re: failure in communicaton between RCX & IR Tower
 
Just to verify the verdict... yes, it did work with w2kpro installed on this laptop. One note is that w2k vanilla does not support wireless 802.1g device, which is what comes with this toshiba satellite p25. It requires service pack 4. -- emabrey (21 years ago, 8-Dec-03, to lugnet.robotics.rcx.robolab)
 
  Re: My problems with adding a Best Fit algorithm for memory management to kernel/mm.c
 
(...) Yes, your summary is correct. Good luck with the rest of your project, Mark (21 years ago, 7-Dec-03, to lugnet.robotics.rcx.legos)
 
  Re: My problems with adding a Best Fit algorithm for memory management to kernel/mm.c
 
(...) Mark, Thanks again thanks for the reply. Yes, my main comcern is that the OS tasks move around only after the first power off & on, no time else. And also it was just a typo, the blocks are in order I was looking at the wrong copy of my layout (...) (21 years ago, 7-Dec-03, to lugnet.robotics.rcx.legos)
 
  Re: My problems with adding a Best Fit algorithm for memory management to kernel/mm.c
 
(...) So, if I understand you correctly, your concern is that the OS tasks move around the first time you power off & on, but not anytime thereafter? Assuming this to be the case, then: 1) When you first download BrickOS, there is a large chunk of (...) (21 years ago, 7-Dec-03, to lugnet.robotics.rcx.legos)