 Robotics / Handy Board / 8567
    Re: Help! Hanyboard Assembly Testing problem! —Sam Weiss
   Hi! I'm still can't get the chip to go into bootstrap mode. I've double checked I've got all the components installed in the correct direction, and inspected the entire board for shorts, and have found none! What can I do?? I'll try resoldering the (...) (22 years ago, 13-Jan-02, to lugnet.robotics.handyboard)
   
        Re: Help! Hanyboard Assembly Testing problem! —Sam Weiss
   Ok, RP4 was fine. I've put a logic tester "MODA" line on the chip (from what I can figure, this is this pin that gets the signal from the stop switch), and it is recieving a signal when I press the stop switch. I verified that the reset pin was (...) (22 years ago, 15-Jan-02, to lugnet.robotics.handyboard)
   
        Re: Help! Hanyboard Assembly Testing problem! —Fred G. Martin
   Sam, can you check the serial input circuit. if this is not correct, then the 6811 won't stay in boot mode. make sure RP4 is a 1Kx4 resistor pack (4 discrete resistors) and not a 1Kx7. also make sure R15 is installed. see (URL) . also, try putting (...) (22 years ago, 15-Jan-02, to lugnet.robotics.handyboard)
   
        Re: Help! Hanyboard Assembly Testing problem! —Sam Weiss
   Hi, Thanks for your reply. RP4 has the part # 88102G, and adjacent pairs of pins have resistance of 1k (ie, 4 discrete resistors). Ok, Tell me if this sounds really strange... R15 is installed, but tested at about 1k ohms, not 47k. I remove the (...) (22 years ago, 16-Jan-02, to lugnet.robotics.handyboard)
   
        Re: Help! Hanyboard Assembly Testing problem!---I think solved! —Sam Weiss
   There was a very undetcible component-side solder bridge between pins 2 and 3 of RP4. I might not know until tomorrow when I can get a replacement for RP4 (apparently I'm not very good at desoldering, and I didn't see the bridge at all until I (...) (22 years ago, 16-Jan-02, to lugnet.robotics.handyboard)
   
        Re: Help! Hanyboard Assembly Testing problem!---I think solved! —Fred G. Martin
   so there was a bridge between Rx and Tx! that would do it. let us know if things are working now. fred (...) (22 years ago, 16-Jan-02, to lugnet.robotics.handyboard)
   
        Re: Help! Hanyboard Assembly Testing problem!---I think solved! —Sam Weiss
   Hey! I've put in the memory, and the LCD screen, and I have interactive C running! Pretty cool that I can print messages to the screen. So problem solved! Anyone have some good instructions on how to properly desolder a part? I almost screwed up my (...) (22 years ago, 17-Jan-02, to lugnet.robotics.handyboard)
 