  RE: 2 questions on Polaroid 6500
 
Hi, Without a 0.1 µF capacitor, your sonar won't work correctly. I don't know why. Martin (22 years ago, 3-Jan-02, to lugnet.robotics.handyboard)
 
  2 questions on Polaroid 6500
 
Hi, I bought a Polaroid 6500 for x-mas and now I’ve got two questions: 1) In the Handy Board Interfacing Diagram of the Polaroid 6500 at the Handyboard page V+ is connected to the pin 9 of the Polaroid 9-pin connector. But the flat cable to the pin (...) (22 years ago, 3-Jan-02, to lugnet.robotics.handyboard)
 
  Re: JRM code and Reset
 
John, I just did the same test, I think what Fred was saying is that IC sets the 0x8000 to accept a startup program if one is loaded. If I poke a 0 to that address then load any program it sets back to 1. I think he was wandering if your IC version (...) (22 years ago, 3-Jan-02, to lugnet.robotics.handyboard)
 
  Re: main() Reset -- THE SAGA ENDS !! ---
 
Awsome!!! Now we are expecting great things from you :-) -Dan (...) (22 years ago, 3-Jan-02, to lugnet.robotics.handyboard)
 
  main() Reset -- THE SAGA ENDS !! ---
 
Fellow Lugnuts, Doe anyone want to purchase a 74HC244 (U5) that "kinda works" ? YES, YES, believe it or not, U5 was my problem !! The mystery is not totally solved, because even using both a logic probe and an o-scope, I cannot see any indication (...) (22 years ago, 3-Jan-02, to lugnet.robotics.handyboard)
 
  Re: JRM code and Reset
 
Matt, The only mod I've made to my HB is to cut the motor power supply "+" trace and use a separate motor power supply. See my post/response to Dan for my explanation of that. After reading your START button question, I triple checked. I don't (...) (22 years ago, 3-Jan-02, to lugnet.robotics.handyboard)
 
  Re: JRM code and Reset
 
Dan, Yes, I did cut the trace for external motor power. I know the HB and the motor power "+" sources are isolated because I not only checked with a VOM, but I removed the motor supply batteries and when I run my motor test program (remember, no (...) (22 years ago, 3-Jan-02, to lugnet.robotics.handyboard)
 
  Re: JRM code and Reset
 
Since it seems like everything else has been checked, I have one other suggestion after looking at my pcode source. If the "start" button on the HB is pressed during power on, the autostart will be disabled. Has your hardware been hacked at all, (...) (22 years ago, 2-Jan-02, to lugnet.robotics.handyboard)
 
  Re: JRM code and Reset
 
Wow, What a bugger! This is one of the strangest cases I've seen. Works fine while connected, but not when reset. Works fine on my board either way. Memory and 68HC11 have been traded out. Scope shows no voltage drop at Mem-power durring reset. Both (...) (22 years ago, 2-Jan-02, to lugnet.robotics.handyboard)
 
  Re: IR Routines
 
(...) Hi Dave, I uploaded a modified version of those IR routines to handyboard.com as well as the Rug Warrior group ((URL) the RW group, I also have a version of pcode v3.1 with bug fixes and new capabilities. Could you convey this information to (...) (22 years ago, 2-Jan-02, to lugnet.robotics.handyboard)