 | | Re: Using Lego IR outside of Lego
|
|
(...) If your laptop has one of the newer (1997) or later super-io chips as the controller for the IR, you may be able to get it to communicate with the tower. The trick is to setup the chip into SHARP IR mode (which transmits data at 38.4k on a (...) (28 years ago, 23-Apr-99, to lugnet.robotics)
|
| |
 | | Re: pneumatic switch control
|
|
At 05:13 AM 4/23/99 -0400, you wrote: <snip> (...) Awesome. It was easy to think of, but I'm not sure that I could have built it as well as you. I particularly like the cam mechanism that you developed, and the use of just one touch sensor. Very (...) (28 years ago, 23-Apr-99, to lugnet.robotics)
|
| |
 | | Pics of 1999 Mindstorms items
|
|
The press room at www.legomindstorms.com has some new pictures of the two new kits due out this year. From these pictures, it's clear that the "Scout" unit - in the Robotics Discovery Kit - is very similar to the RCX; it has only 2 inputs, and (...) (28 years ago, 24-Apr-99, to lugnet.robotics)
|
| |
 | | Reading sensors at equal intervals.
|
|
Is it possible (with the standard firmware) to read the RCX sensors (actually, ideally, to run any old subroutine) at equal intervals, ie like every 100ms or something? (I assume it must be, otherwise you couldn't measure speed with the angle (...) (28 years ago, 24-Apr-99, to lugnet.robotics)
|
| |
 | | Steer kit
|
|
I bought the Steering kit, 5295, and now can't envision how all of the pieces can be used. Does anyone have any examples they could share? -- Did you check the web site first?: (URL) (28 years ago, 24-Apr-99, to lugnet.robotics)
|
| |
 | | Re: Steer kit
|
|
David Cuthill <lego-robotics@crynwr.com> wrote in message news:01BE8DCB.0A59FE...ome.com... (...) One of the models on this page shows some of those parts. Sorry that they are not closeup. (URL) (...) (28 years ago, 24-Apr-99, to lugnet.robotics)
|
| |
 | | Re: Reading sensors at equal intervals.
|
|
(...) By standard firmware, I assume you mean using the byte codes ala NQC or something similar. If you only want semi-precise timing, you can use the wait opcode to delay for approximately 100 ms between sensor samples. If you want something more (...) (28 years ago, 25-Apr-99, to lugnet.robotics)
|
| |
 | | Re: Reading sensors at equal intervals.
|
|
(...) I though that the four "Timer()" values read out in 100ms increments only. Is there a way to get a 1ms timer with NQC? thanks, DLC (28 years ago, 25-Apr-99, to lugnet.robotics)
|
| |
 | | Re: Reading sensors at equal intervals.
|
|
(...) You are right, the timer values as seen by the firmware are in 1/10ths of a second. I lost myself in H8-land, which has a 1 ms timer that gets divided down before being seen by the firmware. -Kekoa (28 years ago, 25-Apr-99, to lugnet.robotics)
|
| |
 | | Re: pneumatic switch control
|
|
Dennis Clark wrote in message ... (...) dropped (...) See demonstartion of the principle: (URL) pneumatic control from menu Eric Brok Visit LEGO ON MY MIND: (URL) Control section: (URL) section: (URL) (28 years ago, 26-Apr-99, to lugnet.robotics)
|