  Re: DATALOG and C
 
(...) I see your point about UploadDatalog, as the tower falls asleep and the PC won't hear the RCX shouting. But SetDatalog seems to work in a program just fine, to set the size of the datalog buffer. BTW, what is the maximum size for the datalog, (...) (26 years ago, 25-Jan-99, to lugnet.robotics)
 
  Re: DATALOG and C
 
(...) SetDatalog is listed in the SDK page 91 as an Immediate Command. If that is true then, if you put the command in with some downloadable RCX instructions, it does whatever it does right then and is not actually sent with the RCX program. (...) (26 years ago, 25-Jan-99, to lugnet.robotics)
 
  Re: DATALOG and C
 
(...) I believe that the maximum size of the datalog is 2033 entries, minus whatever you need for program data. If you want to figure this out dynamically from the PC, get the memory map after downloading all programs to the RCX. The maximum datalog (...) (26 years ago, 25-Jan-99, to lugnet.robotics)
 
  Re: DATALOG and C
 
(...) SetDatalog in the SDK may be Immediate - I haven't worked with the SDK. With NQC, SetDatalog() can be executed from within a program. Dave (26 years ago, 25-Jan-99, to lugnet.robotics)
 
  Re: DATALOG and C
 
(...) It looks like Spirit does NOT download the SetDatalog function. It is an immediate only command from VB. (26 years ago, 27-Jan-99, to lugnet.robotics)