    NXT Ultrasonic reporting wrong values —Patrick J. Levy
   A just get my NXT, and everything works fine, but the ultrasonic sensor is not reporting correct values. No matter what distance or direction it is pointed, the readings changes quickly from 1 to 3 inches (3 to 7 cm) even if the sensor is completely (...) (18 years ago, 15-Oct-06, to lugnet.robotics, lugnet.robotics.nxt)
   
        Re: NXT Ultrasonic reporting wrong values —Brian Davis
     (...) I'm not sure what you mean by "completely stopped" - stationary? I suppose it's possible that you actually have a bad US sensor. If you can find someone with a working one, try swapping sensors with them and see if the problem is isolated to (...) (18 years ago, 15-Oct-06, to lugnet.robotics, lugnet.robotics.nxt)
    
         Re: NXT Ultrasonic reporting wrong values —Patrick J. Levy
      (...) Yes, "stationary" is the correct word... The problem that i bought this one in UK, but i live in Brazil. No one here have this set (Actualy, i don´t know anybody who plays with LEGO mindstorms also...) With BrickxCC watching this sensor I get (...) (18 years ago, 15-Oct-06, to lugnet.robotics, lugnet.robotics.nxt)
    
         Two FLL NXT sets for sale —Liz Bilbro
     This doesn't seem to be posting. Apologies if it posts twice. I have two FLL NXT robot kits for sale. They originally cost $280/set. For each set, I bought an extra rechargeable battery ($50) and light sensor ($17). These sets are brand-new and have (...) (18 years ago, 16-Oct-06, to lugnet.robotics)
   
        Re: NXT Ultrasonic reporting wrong values —Steve Hassenplug
     (...) Is this sensor mounted on a robot? Make sure you don't have anything anywhere in front of the robot. Steve (18 years ago, 15-Oct-06, to lugnet.robotics.nxt)
    
         Re: NXT Ultrasonic reporting wrong values —Patrick J. Levy
     (...) No, is not. I am in "desperate mode", so, by now I am using only the NXT brick and the US, and trying to figure out more information about this condition... I realize now that the black grid in front of the right "eye" of the sensor is turned (...) (18 years ago, 15-Oct-06, to lugnet.robotics.nxt)
    
         Re: NXT Ultrasonic reporting wrong values —Steve Hassenplug
     (...) I don't think that's an issue. In the sensors I have the mesh is not straight. Steve (18 years ago, 15-Oct-06, to lugnet.robotics.nxt)
   
        Re: NXT Ultrasonic reporting wrong values —Patrick J. Levy
   (...) What I discover just now: If I press the light gray conector case behind the sensor case with my nail, it will report the correct values!! but when I release, it stop working again. It seems to be a bad contact inside the sensor. How can I fix (...) (18 years ago, 15-Oct-06, to lugnet.robotics, lugnet.robotics.nxt)
 