In lugnet.robotics, Patrick J. Levy wrote:
> A just get my NXT, and everything works fine, but the ultrasonic sensor is not
> reporting correct values. No matter what distance or direction it is pointed,
> the readings changes quickly from 1 to 3 inches (3 to 7 cm) even if the sensor
> is completely stopped. This readings are from view mode of the NXT display. I
> did already try: Indors, outdors, Light and dark rooms, change the cable, the
> ports, etc.
>
> If anybody experienced this weird behaviour, please let me know...
>
> TIA
>
> Patrick Levy
What I discover just now: If I press the light gray conector case behind the
sensor case with my nail, it will report the correct values!! but when I
release, it stop working again. It seems to be a bad contact inside the sensor.
How can I fix it?
Patrick
|
|
Message is in Reply To:
| | NXT Ultrasonic reporting wrong values
|
| A just get my NXT, and everything works fine, but the ultrasonic sensor is not reporting correct values. No matter what distance or direction it is pointed, the readings changes quickly from 1 to 3 inches (3 to 7 cm) even if the sensor is completely (...) (18 years ago, 15-Oct-06, to lugnet.robotics, lugnet.robotics.nxt)
|