In lugnet.robotics, Patrick J. Levy wrote:
A just get my NXT, and everything works fine, but the ultrasonic sensor is not
reporting correct values. No matter what distance or direction it is pointed,
the readings changes quickly from 1 to 3 inches (3 to 7 cm) even if the sensor
is completely stopped. This readings are from view mode of the NXT display. I
did already try: Indors, outdors, Light and dark rooms, change the cable, the
ports, etc.

If anybody experienced this weird behaviour, please let me know...

TIA

Patrick Levy

What I discover just now: If I press the light gray conector case behind the
sensor case with my nail, it will report the correct values!! but when I
release, it stop working again. It seems to be a bad contact inside the sensor.
How can I fix it?

Patrick



Message is in Reply To:
  NXT Ultrasonic reporting wrong values
 
A just get my NXT, and everything works fine, but the ultrasonic sensor is not reporting correct values. No matter what distance or direction it is pointed, the readings changes quickly from 1 to 3 inches (3 to 7 cm) even if the sensor is completely (...) (18 years ago, 15-Oct-06, to lugnet.robotics, lugnet.robotics.nxt)

8 Messages in This Thread:




Entire Thread on One Page:
Nested:  All | Brief | Compact | Dots
Linear:  All | Brief | Compact
    
Active threads in...

Robotics

 
Verified and Trusted Team of Hackers
3 hours ago

NXT programmable brick

 
Verified and Trusted Team of Hackers
3 hours ago
Custom Search

©2005 LUGNET. All rights reserved. - hosted by steinbruch.info GbR