Subject:
|
Re: Question about RIS version differences
|
Newsgroups:
|
lugnet.robotics
|
Date:
|
Wed, 31 Oct 2001 01:49:52 GMT
|
Viewed:
|
983 times
|
| |
| |
Robolab 2.5 (which supports the USB tower) has the following VLL commands:
1. Send Command over the VLL port to the Microscout (supports both direct
and script commands)
2. Send 7-bit VLL command to the VLL port
3. Send VLL command to another device (it actually mentions the Code Pilot,
which puzzles me since I didn't think it supported VLL)
In lugnet.robotics, "Tilman Sporkert \(webMethods\)" <tilman@webmethods.com>
writes:
> Installing the USB tower adds an entry in the Windows Control Panel for
> tower configuration. This panel has all the necessary options to configure
> the tower for use with a MicroScout (i.e. use visible light instead of
> Infrared). However, I have not seen any software or documentation anywhere
> to do such things from the PC.
>
> Tilman
>
>
> > So, that would seem to imply that it is possible to program a MicroScout
> > from the PC? Using what software? Has anyone actually done this?
> > Brian.
> >
> > -----Original Message-----
> > From: Tilman Sporkert (webMethods) [mailto:tilman@webmethods.com]
> > Sent: Tuesday, October 30, 2001 1:35 PM
> > To: Juergen Stuber; lego-robotics@crynwr.com
> > Subject: RE: Question about RIS version differences
> >
> >
> > > There's one more piece in RIS 2.0 compared to RIS 1.5, a long and
> > > wide fiber optic piece (unlike those in e.g. space shuttle 8480).
> >
> > That goes with the new USB tower, to allow communications with a Micro
> > Scout. You stick one end in a hole in the USB tower, and the
> > other end into
> > a hole in a Micro Scout.
|
|
Message has 2 Replies: | | Re: Question about RIS version differences
|
| An addendum to my previous post. The VLL section of this newsgroup also mentions: 1. A user-written package WINVLL that supports the USB tower and the Microscout. 2. That the Code Pilot does support VLL. (...) (23 years ago, 31-Oct-01, to lugnet.robotics)
|
Message is in Reply To:
| | RE: Question about RIS version differences
|
| Installing the USB tower adds an entry in the Windows Control Panel for tower configuration. This panel has all the necessary options to configure the tower for use with a MicroScout (i.e. use visible light instead of Infrared). However, I have not (...) (23 years ago, 30-Oct-01, to lugnet.robotics)
|
6 Messages in This Thread:
- Entire Thread on One Page:
- Nested:
All | Brief | Compact | Dots
Linear:
All | Brief | Compact
This Message and its Replies on One Page:
- Nested:
All | Brief | Compact | Dots
Linear:
All | Brief | Compact
|
|
|
|