    Re: Using Vision Command as a Smart Sensor —Robert G. Fay
   I made this work with some motor commands. Very cool! This is something I hoped would be developed with Vision Command. Thanks for the posting. -- Bob Fay rfay@we.mediaone.net The Shop (URL) Fay" <rfay@we.mediaone.net> wrote in message (...) (24 years ago, 6-Dec-00, to lugnet.robotics, lugnet.robotics.vc)
   
        Re: Using Vision Command as a Smart Sensor —Michael Gasperi
   "Bob Fay" <rfay@we.mediaone.net> wrote in message news:G55s5H.CHz@lugnet.com... (...) Were you able to make it work with NQC? If it was, I'd like to see the code. Despite the association with my friend Dave Baum, I don't use NQC. (24 years ago, 6-Dec-00, to lugnet.robotics, lugnet.robotics.vc)
   
        Re: Using Vision Command as a Smart Sensor —Robert G. Fay
     I just used one Message. I still don't know how to do your test program. This will start and stop the motor as long as motion is detected in area 2. task main() { while(true) { if (Message()== 2) { OnFwd(OUT_A); Wait(100); Off(OUT_A); } } } -- Bob (...) (24 years ago, 6-Dec-00, to lugnet.robotics, lugnet.robotics.vc)
   
        Re: Using Vision Command as a Smart Sensor —Rainer Balzerowski
   In lugnet.robotics, Michael Gasperi writes: hoped would be developed with Vision Command. Thanks for the posting. (...) Hi folks, i do it in a task like this : int global_message; task Read_VC_Messages () { int j; int local_message = 0; (...) (24 years ago, 6-Dec-00, to lugnet.robotics, lugnet.robotics.vc)
   
        Re: Using Vision Command as a Smart Sensor —Michael Gasperi
   "Rainer Balzerowski" <balze2@gmx.net> wrote in message news:G55v2z.LqB@lugnet.com... (...) or (...) for one (...) I didn't realize VC tried to compensate for the RCX program. I'll fix that comment. Do you think the Spin Left 1.0s command in the (...) (24 years ago, 6-Dec-00, to lugnet.robotics, lugnet.robotics.vc)
   
        Re: Using Vision Command as a Smart Sensor —Robert G. Fay
     This works for me. NQC task main() { while(true) { SetUserDisplay(Message(),0); } } -- Bob Fay rfay@we.mediaone.net The Shop (URL) Gasperi" <gasperi@alynk.com> wrote in message news:G55vn0.D3@lugnet.com... (...) command (...) that (...) the (...) (24 years ago, 6-Dec-00, to lugnet.robotics, lugnet.robotics.vc)
   
        Re: Using Vision Command as a Smart Sensor —Robert G. Fay
     This works for me. NQC task main() { while(true) { SetUserDisplay(Message(),0); } } -- Bob Fay rfay@we.mediaone.net The Shop (URL) Gasperi" <gasperi@alynk.com> wrote in message news:G55vn0.D3@lugnet.com... (...) command (...) that (...) the (...) (24 years ago, 6-Dec-00, to lugnet.robotics, lugnet.robotics.vc)
   
        Re: Using Vision Command as a Smart Sensor —Rainer Balzerowski
   (...) I didn't check this out yet, but i guess it does !!?!! (...) Nice to hear ! Thanks ! Rainer (24 years ago, 6-Dec-00, to lugnet.robotics, lugnet.robotics.vc)
   
        Re: Using Vision Command as a Smart Sensor —Michael Gasperi
    Rainer Balzerowski <balze2@gmx.net> wrote in message news:G55w18.1Ip@lugnet.com... (...) It does slow down VC a little to leave the 1.0 seconds in the Spin Left. You really notice it if you put long numbers like 100 seconds in. I've incorporated (...) (24 years ago, 7-Dec-00, to lugnet.robotics, lugnet.robotics.vc)
 